This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Real-world patient - creatinine
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Observation/f204> a fhir:Observation; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "f204"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f204</p><p><b>identifier</b>: 1304-03720-Creatinine</p><p><b>status</b>: final</p><p><b>code</b>: Creatinine(Serum) <span>(Details : {https://intranet.aumc.nl/labtestcodes code '20005' = '??', given as 'Creatinine(Serum)'})</span></p><p><b>subject</b>: <a>Roel</a></p><p><b>issued</b>: 04/04/2013 2:34:00 PM</p><p><b>performer</b>: <a>Luigi Maas</a></p><p><b>value</b>: 122 umol/L<span> (Details: SNOMED CT code 258814008 = 'Micromole/liter (qualifier value)')</span></p><p><b>interpretation</b>: Serum creatinine raised <span>(Details : {SNOMED CT code '166717003' = 'Serum creatinine raised (finding)', given as 'Serum creatinine raised'}; {http://hl7.org/fhir/v2/0078 code 'H' = 'High)</span></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td><td><b>Meaning</b></td></tr><tr><td>*</td><td>64</td><td>104</td><td>Normal Range <span>(Details : {http://hl7.org/fhir/referencerange-meaning code 'normal' = 'Normal Range', given as 'Normal Range'})</span></td></tr></table></div>" ]; fhir:Observation.identifier [ fhir:index 0; fhir:Identifier.system [ fhir:value "https://intranet.aumc.nl/labvalues" ]; fhir:Identifier.value [ fhir:value "1304-03720-Creatinine" ] ]; fhir:Observation.status [ fhir:value "final"]; fhir:Observation.code [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "https://intranet.aumc.nl/labtestcodes" ]; fhir:Coding.code [ fhir:value "20005" ]; fhir:Coding.display [ fhir:value "Creatinine(Serum)" ] ] ]; fhir:Observation.subject [ fhir:link <http://hl7.org/fhir/Patient/f201>; fhir:Reference.reference [ fhir:value "Patient/f201" ]; fhir:Reference.display [ fhir:value "Roel" ] ]; fhir:Observation.issued [ fhir:value "2013-04-04T14:34:00+01:00"^^xsd:dateTime]; fhir:Observation.performer [ fhir:index 0; fhir:link <http://hl7.org/fhir/Practitioner/f202>; fhir:Reference.reference [ fhir:value "Practitioner/f202" ]; fhir:Reference.display [ fhir:value "Luigi Maas" ] ]; fhir:Observation.valueQuantity [ fhir:Quantity.value [ fhir:value "122"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "umol/L" ]; fhir:Quantity.system [ fhir:value "http://snomed.info/sct" ]; fhir:Quantity.code [ fhir:value "258814008" ] ]; fhir:Observation.interpretation [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:concept sct:166717003; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "166717003" ]; fhir:Coding.display [ fhir:value "Serum creatinine raised" ] ], [ fhir:index 1; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0078" ]; fhir:Coding.code [ fhir:value "H" ] ] ]; fhir:Observation.referenceRange [ fhir:index 0; fhir:Observation.referenceRange.low [ fhir:Quantity.value [ fhir:value "64"^^xsd:decimal ] ]; fhir:Observation.referenceRange.high [ fhir:Quantity.value [ fhir:value "104"^^xsd:decimal ] ]; fhir:Observation.referenceRange.meaning [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/referencerange-meaning" ]; fhir:Coding.code [ fhir:value "normal" ]; fhir:Coding.display [ fhir:value "Normal Range" ] ] ] ] . <http://hl7.org/fhir/Patient/f201> a fhir:Patient . <http://hl7.org/fhir/Practitioner/f202> a fhir:Practitioner . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.