This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
Order for an injectable medication - Lorazepam - active - with link to encounter, reasonCode and dosageInstruction (id = "medrx0315")
<MedicationOrder xmlns="http://hl7.org/fhir"> <id value="medrx0315"/> <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: medrx0315</p><p><b>contained</b>: </p><p><b>identifier</b>: 12345689 (OFFICIAL)</p><p><b>status</b>: active</p><p><b>medication</b>: id: med0313; Lorazepam 2mg/ml injection solution 1ml vial (product) <span>(Details : {SNOMED CT code '400621001' = 'Lorazepam 2mg/mL injection solution 1mL vial (product)', given as 'Lorazepam 2mg/ml injection solution 1ml vial (product)'})</span>; </p><p><b>patient</b>: <a>Donald Duck</a></p><p><b>encounter</b>: <a>encounter who leads to this prescription</a></p><p><b>dateWritten</b>: 15/01/2015</p><p><b>prescriber</b>: <a>Patrick Pump</a></p><p><b>reasonCode</b>: Epilepsy (disorder) <span>(Details : {SNOMED CT code '84757009' = 'Epilepsy', given as 'Epilepsy (disorder)'})</span></p><h3>DosageInstructions</h3><table><tr><td>-</td><td><b>Text</b></td><td><b>Timing</b></td><td><b>AsNeeded[x]</b></td><td><b>Route</b></td><td><b>Method</b></td><td><b>Dose[x]</b></td><td><b>Rate[x]</b></td></tr><tr><td>*</td><td>0.05 - 0.1mg/kg IV over 2-5 minutes every 15 minutes as needed</td><td>Do Once per 15 minutes</td><td>true</td><td>Intravenous <span>(Details : {SNOMED CT code '255560000' = 'Intravenous (qualifier value)', given as 'Intravenous'})</span></td><td>Push - dosing instruction imperative (qualifier value) <span>(Details : {SNOMED CT code '420620005' = 'Push - dosing instruction imperative (qualifier value)', given as 'Push - dosing instruction imperative (qualifier value)'})</span></td><td>0.05-0.1 mg/kg</td><td>2-5 min</td></tr></table></div></text><contained> <Medication> <id value="med0313"/> <code> <coding> <system value="http://snomed.info/sct"/> <code value="400621001"/> <display value="Lorazepam 2mg/ml injection solution 1ml vial (product)"/> </coding> </code> <isBrand value="false"/> <product> <form> <coding> <system value="http://snomed.info/sct"/> <code value="385219001"/> <display value="Injection solution (qualifier value)"/> </coding> </form> <ingredient> <itemCodeableConcept> <coding> <system value="http://snomed.info/sct"/> <code value="387106007"/> <display value="Lorazepam (substance)"/> </coding> </itemCodeableConcept> <amount> <numerator> <value value="2"/> <system value="http://unitsofmeasure.org"/> <code value="mg"/> </numerator> <denominator> <value value="1"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </amount> </ingredient> </product> </Medication> </contained> <identifier> <use value="official"/> <system value="http://www.bmc.nl/portal/prescriptions"/> <value value="12345689"/> </identifier> <status value="active"/> <medicationReference> <!-- Linked to a RESOURCE Medication --> <reference value="#med0313"/> </medicationReference> <patient> <!-- Linked to the resource patient who needs the medication --> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </patient> <encounter> <!-- Linked to a resource Encounter between patient and practitioner --> <reference value="Encounter/f001"/> <display value="encounter who leads to this prescription"/> </encounter> <dateWritten value="2015-01-15"/> <prescriber> <!-- Linked to the practitioner who treats patient --> <reference value="Practitioner/f007"/> <display value="Patrick Pump"/> </prescriber> <reasonCode> <coding> <system value="http://snomed.info/sct"/> <code value="84757009"/> <display value="Epilepsy (disorder)"/> </coding> </reasonCode> <dosageInstruction> <text value="0.05 - 0.1mg/kg IV over 2-5 minutes every 15 minutes as needed"/> <timing> <repeat> <frequency value="1"/> <period value="15"/> <periodUnit value="min"/> </repeat> </timing> <asNeededBoolean value="true"/> <route> <coding> <system value="http://snomed.info/sct"/> <code value="255560000"/> <display value="Intravenous"/> </coding> </route> <method> <coding> <system value="http://snomed.info/sct"/> <code value="420620005"/> <display value="Push - dosing instruction imperative (qualifier value)"/> </coding> </method> <doseRange> <low> <value value="0.05"/> <unit value="mg/kg"/> <system value="http://unitsofmeasure.org"/> <code value="mg/kg"/> </low> <high> <value value="0.1"/> <unit value="mg/kg"/> <system value="http://unitsofmeasure.org"/> <code value="mg/kg"/> </high> </doseRange> <rateRange> <low> <value value="2"/> <unit value="min"/> <system value="http://unitsofmeasure.org"/> <code value="min"/> </low> <high> <value value="5"/> <unit value="min"/> <system value="http://unitsofmeasure.org"/> <code value="min"/> </high> </rateRange> </dosageInstruction> </MedicationOrder>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.