This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Dispense for Vicodin - in progress - PRN with pre-condition
{ "resourceType": "MedicationDispense", "id": "meddisp0321", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: meddisp0321</p><p><b>status</b>: in-progress</p><p><b>medication</b>: Vicodin 5mg Hydrocodone, 500mg Acetaminophen tablet <span>(Details : {http://hl7.org/fhir/sid/ndc code '49999-051-30' = '??', given as 'Vicodin 5mg Hydrocodone, 500mg Acetaminophen tablet '})</span></p><p><b>patient</b>: <a>Donald Duck</a></p><p><b>dispenser</b>: <a>Rob van den Berk</a></p><p><b>authorizingPrescription</b>: <a>MedicationOrder/medrx0321</a></p><p><b>type</b>: partial Fill <span>(Details : {http://hl7.org/fhir/v3/ActPharmacySupplyType code 'PF' = '??', given as 'partial Fill'})</span></p><p><b>quantity</b>: 30 TAB<span> (Details: http://unitsofmeasure.org code TAB = 'TAB')</span></p><p><b>daysSupply</b>: 10 Day<span> (Details: http://unitsofmeasure.org code d = 'd')</span></p><p><b>whenPrepared</b>: 15/01/2015 9:20:00 PM</p><h3>DosageInstructions</h3><table><tr><td>-</td><td><b>Text</b></td><td><b>AdditionalInstructions</b></td><td><b>Timing</b></td><td><b>AsNeeded[x]</b></td><td><b>Route</b></td><td><b>Dose[x]</b></td></tr><tr><td>*</td><td>1 tablet every four hours as needed for pain</td><td>Warning. May cause drowsiness. If affected do not drive or operate machinery. Avoid alcoholic drink (qualifier value) <span>(Details : {SNOMED CT code '418914006' = 'Warning. May cause drowsiness. If affected do not drive or operate machinery. Avoid alcoholic drink (qualifier value)', given as 'Warning. May cause drowsiness. If affected do not drive or operate machinery. Avoid alcoholic drink (qualifier value)'})</span></td><td>Do Once per 4 hours</td><td>Fibromyalgia (disorder) <span>(Details : {SNOMED CT code '203082005' = 'Fibromyalgia (disorder)', given as 'Fibromyalgia (disorder)'})</span></td><td>Oral Route <span>(Details : {SNOMED CT code '26643006' = 'Oral route (qualifier value)', given as 'Oral Route'})</span></td><td>1 TAB<span> (Details: http://hl7.org/fhir/ValueSet/v3-orderableDrugForm code TAB = '??')</span></td></tr></table></div>" }, "status": "in-progress", "medicationCodeableConcept": { "coding": [ { "system": "http://hl7.org/fhir/sid/ndc", "code": "49999-051-30", "display": "Vicodin 5mg Hydrocodone, 500mg Acetaminophen tablet " } ] }, "patient": { "reference": "Patient/pat1", "display": "Donald Duck" }, "dispenser": { "reference": "Practitioner/f006", "display": "Rob van den Berk" }, "authorizingPrescription": [ { "reference": "MedicationOrder/medrx0321" } ], "type": { "coding": [ { "system": "http://hl7.org/fhir/v3/ActPharmacySupplyType", "code": "PF", "display": "partial Fill" } ] }, "quantity": { "value": 30, "system": "http://unitsofmeasure.org", "code": "TAB" }, "daysSupply": { "value": 10, "unit": "Day", "system": "http://unitsofmeasure.org", "code": "d" }, "whenPrepared": "2015-01-15T10:20:00Z", "dosageInstruction": [ { "text": "1 tablet every four hours as needed for pain", "additionalInstructions": [ { "coding": [ { "system": "http://snomed.info/sct", "code": "418914006", "display": "Warning. May cause drowsiness. If affected do not drive or operate machinery. Avoid alcoholic drink (qualifier value)" } ] } ], "timing": { "repeat": { "frequency": 1, "period": 4, "periodUnit": "h" } }, "asNeededCodeableConcept": { "coding": [ { "system": "http://snomed.info/sct", "code": "203082005", "display": "Fibromyalgia (disorder)" } ] }, "route": { "coding": [ { "system": "http://snomed.info/sct", "code": "26643006", "display": "Oral Route" } ] }, "doseQuantity": { "value": 1, "unit": "TAB", "system": "http://hl7.org/fhir/ValueSet/v3-orderableDrugForm", "code": "TAB" } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.