This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Dispense for Potassium Chloride Admixture - stopped - with eventHistory and rate range for dosage (id = "meddisp0313")
<MedicationDispense xmlns="http://hl7.org/fhir"> <id value="meddisp0313"/> <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: meddisp0313</p><p><b>contained</b>: </p><p><b>status</b>: stopped</p><p><b>medication</b>: Potassium Chloride 20mEq in 1L Normal Saline. Generated Summary: id: med0317</p><p><b>patient</b>: <a>Donald Duck</a></p><p><b>dispenser</b>: <a>Rob van den Berk</a></p><p><b>authorizingPrescription</b>: <a>MedicationOrder/medrx0322</a></p><p><b>type</b>: First Fill <span>(Details : {http://hl7.org/fhir/ValueSet/v3-ActPharmacySupplyType code 'FF' = '??', given as 'First Fill'})</span></p><p><b>quantity</b>: 1000 ml<span> (Details: http://unitsofmeasure.org code ml = 'ml')</span></p><p><b>daysSupply</b>: 1 Day<span> (Details: http://unitsofmeasure.org code d = 'd')</span></p><p><b>whenPrepared</b>: 28/04/2016 7:13:00 AM</p><p><b>whenHandedOver</b>: 28/04/2016 7:13:00 AM</p><h3>DosageInstructions</h3><table><tr><td>-</td><td><b>Text</b></td><td><b>Timing</b></td><td><b>Route</b></td><td><b>Dose[x]</b></td><td><b>Rate[x]</b></td></tr><tr><td>*</td><td>KCl 20 mEq in 1 L 0.9%NS IV at 100 ml/hr</td><td>Do Once per 1 days</td><td>Intravenous route (qualifier value) <span>(Details : {SNOMED CT code '47625008' = 'Intravenous route (qualifier value)', given as 'Intravenous route (qualifier value)'})</span></td><td>20 mEq<span> (Details: http://unitsofmeasure.org code mEq = 'mEq')</span></td><td>100 mL<span> (Details: http://unitsofmeasure.org code mL = 'mL')</span>/1 h<span> (Details: http://unitsofmeasure.org code h = 'h')</span></td></tr></table><h3>EventHistories</h3><table><tr><td>-</td><td><b>Status</b></td><td><b>DateTime</b></td></tr><tr><td>*</td><td>completed</td><td>28/04/2016 7:13:00 AM</td></tr></table></div></text><contained> <Medication> <id value="med0317"/> <product> <form> <coding> <system value="http://snomed.info/sct"/> <code value="385219001"/> <display value="Injection Solution (qualifier value)"/> </coding> <text value="Injection Solution (qualifier value)"/> </form> <ingredient> <itemCodeableConcept> <coding> <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> <code value="204520"/> <display value="Potassium Chloride"/> </coding> </itemCodeableConcept> <amount> <numerator> <value value="2"/> <system value="http://unitsofmeasure.org"/> <code value="mEq"/> </numerator> <denominator> <value value="1"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </amount> </ingredient> <ingredient> <itemCodeableConcept> <coding> <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> <code value="313002"/> <display value="Sodium Chloride 0.9% injectable solution"/> </coding> </itemCodeableConcept> <amount> <numerator> <value value="0.9"/> <system value="http://unitsofmeasure.org"/> <code value="g"/> </numerator> <denominator> <value value="100"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </amount> </ingredient> </product> </Medication> </contained> <status value="stopped"/> <medicationReference> <!-- Linked to a RESOURCE Medication --> <reference value="#med0317"/> <display value="Potassium Chloride 20mEq in 1L Normal Saline"/> </medicationReference> <patient> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </patient> <dispenser> <reference value="Practitioner/f006"/> <display value="Rob van den Berk"/> </dispenser> <authorizingPrescription> <reference value="MedicationOrder/medrx0322"/> </authorizingPrescription> <type> <coding> <system value="http://hl7.org/fhir/ValueSet/v3-ActPharmacySupplyType"/> <code value="FF"/> <display value="First Fill"/> </coding> </type> <quantity> <value value="1000"/> <system value="http://unitsofmeasure.org"/> <code value="ml"/> </quantity> <daysSupply> <value value="1"/> <unit value="Day"/> <system value="http://unitsofmeasure.org"/> <code value="d"/> </daysSupply> <whenPrepared value="2016-04-28T07:13:00+05:00"/> <whenHandedOver value="2016-04-28T07:13:00+05:00"/> <dosageInstruction> <text value="KCl 20 mEq in 1 L 0.9%NS IV at 100 ml/hr"/> <timing> <repeat> <frequency value="1"/> <period value="1"/> <periodUnit value="d"/> </repeat> </timing> <route> <coding> <system value="http://snomed.info/sct"/> <code value="47625008"/> <display value="Intravenous route (qualifier value)"/> </coding> </route> <doseQuantity> <value value="20"/> <unit value="mEq"/> <system value="http://unitsofmeasure.org"/> <code value="mEq"/> </doseQuantity> <rateRatio> <numerator> <value value="100"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </numerator> <denominator> <value value="1"/> <system value="http://unitsofmeasure.org"/> <code value="h"/> </denominator> </rateRatio> </dosageInstruction> <eventHistory> <status value="completed"/> <dateTime value="2016-04-28T07:13:00+05:00"/> </eventHistory> </MedicationDispense>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.