This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Real-world patient example
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/DiagnosticReport/f201> a fhir:DiagnosticReport; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "f201"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f201</p><p><b>status</b>: final</p><p><b>category</b>: Radiology <span>(Details : {SNOMED CT code '394914008' = 'Radiology - specialty (qualifier value)', given as 'Radiology'}; {http://hl7.org/fhir/v2/0074 code 'RAD' = 'Radiology)</span></p><p><b>code</b>: CT of head-neck <span>(Details : {SNOMED CT code '429858000' = 'Computed tomography of head and neck (procedure)', given as 'Computed tomography (CT) of head and neck'})</span></p><p><b>subject</b>: <a>Roel</a></p><p><b>effective</b>: 01/12/2012 12:00:00 PM</p><p><b>issued</b>: 01/12/2012 12:00:00 PM</p><p><b>performer</b>: <a>Blijdorp MC</a></p><p><b>imagingStudy</b>: HEAD and NECK CT DICOM imaging study</p><p><b>conclusion</b>: CT brains: large tumor sphenoid/clivus.</p><p><b>codedDiagnosis</b>: Malignant tumor of craniopharyngeal duct <span>(Details : {SNOMED CT code '188340000' = 'Malignant tumor of craniopharyngeal duct (disorder)', given as 'Malignant tumor of craniopharyngeal duct'})</span></p></div>" ]; fhir:DiagnosticReport.status [ fhir:value "final"]; fhir:DiagnosticReport.category [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:concept sct:394914008; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "394914008" ]; fhir:Coding.display [ fhir:value "Radiology" ] ], [ fhir:index 1; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0074" ]; fhir:Coding.code [ fhir:value "RAD" ] ] ]; fhir:DiagnosticReport.code [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:concept sct:429858000; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "429858000" ]; fhir:Coding.display [ fhir:value "Computed tomography (CT) of head and neck" ] ]; fhir:CodeableConcept.text [ fhir:value "CT of head-neck" ] ]; fhir:DiagnosticReport.subject [ fhir:link <http://hl7.org/fhir/Patient/f201>; fhir:Reference.reference [ fhir:value "Patient/f201" ]; fhir:Reference.display [ fhir:value "Roel" ] ]; fhir:DiagnosticReport.effectiveDateTime [ fhir:value "2012-12-01T12:00:00+01:00"^^xsd:dateTime]; fhir:DiagnosticReport.issued [ fhir:value "2012-12-01T12:00:00+01:00"^^xsd:dateTime]; fhir:DiagnosticReport.performer [ fhir:index 0; fhir:link <http://hl7.org/fhir/Organization/f203>; fhir:Reference.reference [ fhir:value "Organization/f203" ]; fhir:Reference.display [ fhir:value "Blijdorp MC" ] ]; fhir:DiagnosticReport.imagingStudy [ fhir:index 0; fhir:Reference.display [ fhir:value "HEAD and NECK CT DICOM imaging study" ] ]; fhir:DiagnosticReport.conclusion [ fhir:value "CT brains: large tumor sphenoid/clivus."]; fhir:DiagnosticReport.codedDiagnosis [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; fhir:concept sct:188340000; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "188340000" ]; fhir:Coding.display [ fhir:value "Malignant tumor of craniopharyngeal duct" ] ] ] . <http://hl7.org/fhir/Patient/f201> a fhir:Patient . <http://hl7.org/fhir/Organization/f203> a fhir:Organization . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.