This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
USLab Ratio Observation Profile Example: Dengue Titer (id = "obs-uslab-example4")
<Observation xmlns="http://hl7.org/fhir"> <id value="obs-uslab-example4"/> <!-- FHIR build is generating the narratives <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <ul> <li> obs-uslab-example4.xml</li> <li> id: uslab-example4</li> <li> Name: USLab Observation Example4</li> <li>Description: USLab Ratio Observation Profile Canonical Example: Dengue Virus</li> </ul> </div> </text> --> <!-- extension for specimen reject goes here - not for this use case <extension url="http://hl7.org/fhir/StructureDefinition/uslab-specimenrejectreason"> <valueCodeableConcept> <coding> <system value="http://hl7.org/fhir/v2/0490"/> <code value="EX"/> <display value="Expired"/> </coding> </valueCodeableConcept> </extension> --> <!-- extension for observation kindt goes here --> <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: obs-uslab-example4</p><p><b>identifier</b>: lab test result ID = 4567 (OFFICIAL)</p><p><b>status</b>: final</p><p><b>code</b>: Dengue IgM Titer <span>(Details : {LOINC code '6812-2' = 'Dengue virus IgM Ab [Titer] in Serum', given as 'Dengue virus IgM Ab [Titer] in Serum'}; {urn:oid:2.16.840.1.113883.3.72.5.24 code 'DGIGM' = '??', given as 'Dengue IgM QN'})</span></p><p><b>subject</b>: <a>Todd Lerr</a></p><p><b>effective</b>: 05/12/2014</p><p><b>issued</b>: 06/12/2014 3:42:15 PM</p><p><b>performer</b>: <a>Dr Leonard T Bloodraw Jr</a></p><p><b>value</b>: 1/256</p><p><b>interpretation</b>: High <span>(Details : {http://hl7.org/fhir/v2/0078 code 'H' = 'High)</span></p><p><b>specimen</b>: <a>Bloo sample</a></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Text</b></td></tr><tr><td>*</td><td><1:64</td></tr></table></div></text><extension url="http://hl7.org/fhir/StructureDefinition/uslab-observationkind"> <valueCode value="result"/> </extension> <identifier> <use value="official"/> <type> <text value="lab test result ID"/> </type> <system value="http://lis.acmelabs.org/identifiers/labtestresult"/> <value value="4567"/> </identifier> <status value="final"/> <!-- EH : The local and /or LOINC test codes go here --> <code> <!-- EH: LOINC code goes here --> <coding> <system value="http://loinc.org"/> <code value="6812-2"/> <display value="Dengue virus IgM Ab [Titer] in Serum"/> <!-- EH: LOINC code goes here --> </coding> <coding> <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/> <code value="DGIGM"/> <display value="Dengue IgM QN"/> </coding> <text value="Dengue IgM Titer"/> </code> <subject> <reference value="Patient/patient-uslab-example1"/> <display value="Todd Lerr"/> </subject> <effectiveDateTime value="2014-12-05"/> <!-- EH: Showing dateTime to ss with TZO although only needed to Day --> <issued value="2014-12-06T15:42:15-08:00"/> <performer> <reference value="Practitioner/pract-uslab-example1"/> <display value="Dr Leonard T Bloodraw Jr"/> </performer> <!-- In FHIR, units may be represented twice. Once in the agreed human representation, and once in a coded form. Both is best, since it's not always possible to infer one from the other in code. When a computable unit is provided, UCUM (http://unitsofmeasure.org) is always preferred, but it doesn't provide notional units (such as "tablet"), etc. For these, something else is required (e.g. Snomed-CT) --> <valueRatio> <numerator> <value value="1"/> </numerator> <denominator> <value value="256"/> </denominator> </valueRatio> <!-- eH dataabsent reason would go here if valueQuantity was empty e.g.: <dataAbsentReason value="error"/> --> <interpretation> <coding> <system value="http://hl7.org/fhir/v2/0078"/> <code value="H"/> </coding> </interpretation> <specimen> <reference value="Specimen/spec-uslab-example1"/> <display value="Bloo sample"/> </specimen> <referenceRange> <text value="<1:64"/> </referenceRange> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.