This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions 
Definition for Value SetReasons for rejecting goal codes
{
"resourceType": "ValueSet",
"id": "qicore-goal-reason-rejected",
"meta": {
"lastUpdated": "2016-03-31T08:01:25.570+11:00",
"profile": [
"http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"
]
},
"text": {
"status": "generated",
"div": "<div>!-- Snipped for Brevity --></div>"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/valueset-oid",
"valueUri": "urn:oid:2.16.840.1.113883.4.642.2.623"
}
],
"url": "http://hl7.org/fhir/ValueSet/qicore-goal-reason-rejected",
"version": "1.4.0",
"name": "Reasons for rejecting goal codes",
"status": "draft",
"experimental": true,
"publisher": "HL7 Clinical Quality Information (CQI) Work Group",
"contact": [
{
"telecom": [
{
"system": "other",
"value": "http://www.hl7.org/Special/committees/cqi"
}
]
}
],
"date": "2016-03-31T08:01:25+11:00",
"description": "The value set to instantiate this attribute should be drawn from a terminologically robust code system that consists of or contains concepts to support the goal process, in particular the process and reasons for rejecting a goal. This value set is provided as a suggestive example.",
"copyright": "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement.",
"compose": {
"include": [
{
"system": "http://hl7.org/fhir/v3/ActReason",
"concept": [
{
"fhir_comments": [
" todo: this is a starting list. needs more reason codes ",
" _SchedulingActReason ",
" Unexpected Block (of Schedule) "
],
"code": "BLK"
},
{
"fhir_comments": [
" Patient Deceased "
],
"code": "DEC"
},
{
"fhir_comments": [
" No Financial Backing "
],
"code": "FIN"
},
{
"fhir_comments": [
" Medical Status Altered "
],
"code": "MED"
},
{
"fhir_comments": [
" _ControlActNullificationReasonCode ",
" altered decision "
],
"code": "ALTD"
}
]
},
{
"system": "http://snomed.info/sct",
"filter": [
{
"property": "concept",
"op": "is-a",
"value": "410521004",
"_value": {
"fhir_comments": [
" Pre-starting action status / Not to be done codes "
]
}
}
]
}
]
}
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.