This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Oxygen Saturation Example (DeviceMetricObservation profile)
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xs: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir//Observation/satO2> a fhir:Observation; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "satO2"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ] ]; fhir:Observation.identifier [ fhir:index 0; fhir:Identifier.system [ fhir:value "http://goodcare.org/observation/id" ]; fhir:Identifier.value [ fhir:value "o1223435-10" ] ]; fhir:Observation.status [ fhir:value "final"]; fhir:Observation.code [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "https://rtmms.nist.gov" ]; fhir:Coding.code [ fhir:value "150456" ]; fhir:Coding.display [ fhir:value "MDC_PULS_OXIM_SAT_O2" ] ] ]; fhir:Observation.subjectReference [ fhir:reference <http://hl7.org/fhir/Patient/example>; fhir:Reference.reference [ fhir:value "Patient/example" ] ]; fhir:Observation.effectiveDateTime [ fhir:value "2014-12-05T09:30:10+01:00"^^xs:dateTime]; fhir:Observation.valueQuantity [ fhir:Quantity.value [ fhir:value "95"^^xs:decimal ]; fhir:Quantity.unit [ fhir:value "%" ]; fhir:Quantity.system [ fhir:value "https://rtmms.nist.gov" ]; fhir:Quantity.code [ fhir:value "262688" ] ]; fhir:Observation.interpretation [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0078" ]; fhir:Coding.code [ fhir:value "N" ]; fhir:Coding.display [ fhir:value "Normal" ] ]; fhir:CodeableConcept.text [ fhir:value "Normal (applies to non-numeric results)" ] ]; fhir:Observation.deviceReference [ fhir:reference <http://hl7.org/fhir/DeviceMetric/example>; fhir:Reference.reference [ fhir:value "DeviceMetric/example" ] ]; fhir:Observation.referenceRange [ fhir:index 0; fhir:Observation.referenceRange.low [ fhir:Quantity.value [ fhir:value "90"^^xs:decimal ]; fhir:Quantity.unit [ fhir:value "%" ]; fhir:Quantity.system [ fhir:value "https://rtmms.nist.gov" ]; fhir:Quantity.code [ fhir:value "262688" ] ]; fhir:Observation.referenceRange.high [ fhir:Quantity.value [ fhir:value "99"^^xs:decimal ]; fhir:Quantity.unit [ fhir:value "%" ]; fhir:Quantity.system [ fhir:value "https://rtmms.nist.gov" ]; fhir:Quantity.code [ fhir:value "262688" ] ] ]. # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.