This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Blood Pressure Measurement cancelled
{ "resourceType": "Observation", "id": "blood-pressure-cancel", "meta": { "lastUpdated": "2014-01-30T22:35:23+11:00" }, "text": { "fhir_comments": [ " \tEH Narrative created by build\n\t<text>\n\t\t<status value=\"generated\"/>\n\t\t<div xmlns=\"http://www.w3.org/1999/xhtml\">Sept 17, 2012: Systolic Blood pressure 107/60 mmHg (low)</div>\n\t</text>\n " ], "status": "generated", "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: blood-pressure-cancel</p><p><b>meta</b>: </p><p><b>identifier</b>: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281</p><p><b>status</b>: cancelled</p><p><b>code</b>: Blood pressure systolic & diastolic <span>(Details : {LOINC code '55284-4' = 'Blood pressure systolic and diastolic', given as 'Blood pressure systolic & diastolic'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>effective</b>: 17/09/2012</p><p><b>performer</b>: <a>Practitioner/example</a></p><p><b>interpretation</b>: Below low normal <span>(Details : {http://hl7.org/fhir/v2/0078 code 'L' = 'Low', given as 'low'})</span></p><p><b>comment</b>: In this example, the blood pressure measurements are not available due to cancellation of the order. Data absent reason is present for each component</p><p><b>bodySite</b>: Right arm <span>(Details : {SNOMED CT code '368209003' = 'Right upper arm structure (body structure)', given as 'Right arm'})</span></p><blockquote><p><b>component</b></p><p><b>code</b>: Systolic blood pressure <span>(Details : {LOINC code '8480-6' = 'Systolic blood pressure', given as 'Systolic blood pressure'}; {SNOMED CT code '271649006' = 'Systolic blood pressure (observable entity)', given as 'Systolic blood pressure'}; {http://acme.org/devices/clinical-codes code 'bp-s' = '??', given as 'Systolic Blood pressure'})</span></p><p><b>dataAbsentReason</b>: Not Asked <span>(Details : {http://hl7.org/fhir/data-absent-reason code 'not-asked' = 'Not Asked', given as 'Not Asked'})</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: Diastolic blood pressure <span>(Details : {LOINC code '8462-4' = 'Diastolic blood pressure', given as 'Diastolic blood pressure'})</span></p><p><b>dataAbsentReason</b>: Not Asked <span>(Details : {http://hl7.org/fhir/data-absent-reason code 'not-asked' = 'Not Asked', given as 'Not Asked'})</span></p></blockquote></div>" }, "identifier": [ { "system": "urn:ietf:rfc:3986", "value": "urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281" } ], "status": "cancelled", "code": { "coding": [ { "system": "http://loinc.org", "code": "55284-4", "display": "Blood pressure systolic & diastolic" } ] }, "subject": { "reference": "Patient/example" }, "effectiveDateTime": "2012-09-17", "performer": [ { "reference": "Practitioner/example" } ], "interpretation": { "fhir_comments": [ " an interpretation offered to the combination observation\n generally, it would only be appropriate to offer an interpretation\n of an observation that has no value if it has \"COMP\" (component)\n observations " ], "coding": [ { "system": "http://hl7.org/fhir/v2/0078", "code": "L", "display": "low" } ], "text": "Below low normal" }, "comment": "In this example, the blood pressure measurements are not available due to cancellation of the order. Data absent reason is present for each component", "bodySite": { "fhir_comments": [ " for an observation with components, these cannot disagree with the flags on the components " ], "coding": [ { "system": "http://snomed.info/sct", "code": "368209003", "display": "Right arm" } ] }, "component": [ { "code": { "fhir_comments": [ " \n Observations are often coded in multiple code systems.\n - LOINC provides a very specific code (though not usefully more specific in this particular case)\n - snomed provides a clinically relevant code that is usually less granular than LOINC\n - the source system provides its own code, which may be less or more granular than LOINC\n\t this instance shows the concept. The other codes only have a LOINC code ", " that shows the concept. The next two names only have a LOINC code " ], "coding": [ { "fhir_comments": [ " LOINC - always recommended to have a LOINC code " ], "system": "http://loinc.org", "code": "8480-6", "display": "Systolic blood pressure" }, { "fhir_comments": [ " SNOMED CT Codes - becoming more common " ], "system": "http://snomed.info/sct", "code": "271649006", "display": "Systolic blood pressure" }, { "fhir_comments": [ " Also, a local code specific to the source system " ], "system": "http://acme.org/devices/clinical-codes", "code": "bp-s", "display": "Systolic Blood pressure" } ] }, "dataAbsentReason": { "fhir_comments": [ " no value due to some error \n <valueQuantity>\n <value value=\"107\"/>\n <unit value=\"mm[Hg]\"/>\n </valueQuantity>\n " ], "coding": [ { "system": "http://hl7.org/fhir/data-absent-reason", "code": "not-asked", "display": "Not Asked" } ] } }, { "code": { "coding": [ { "system": "http://loinc.org", "code": "8462-4", "display": "Diastolic blood pressure" } ] }, "dataAbsentReason": { "fhir_comments": [ " no value due to some error \n <valueQuantity>\n <value value=\"60\"/>\n <unit value=\"mm[Hg]\"/>\n </valueQuantity>\n " ], "coding": [ { "system": "http://hl7.org/fhir/data-absent-reason", "code": "not-asked", "display": "Not Asked" } ] } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.