STU 3 Candidate

This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3

Device-example-udi1.ttl

Raw Turtle, JSON-LD

Implantable device/UDI example

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/sct/> .
@prefix xs: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir//Device/example-udi1> a fhir:Device;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "example-udi1"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ]
  ];
  fhir:Device.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "http://acme.com/devices/pacemakers/octane/serial" ];
     fhir:Identifier.value [ fhir:value "1234-5678-90AB-CDEF" ]
  ];
  fhir:Device.identifier [
     fhir:index 1;
     fhir:Identifier.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/identifier-type" ];
         fhir:Coding.code [ fhir:value "SNO" ]       ]     ];
     fhir:Identifier.value [ fhir:value "10987654d321" ]
  ];
  fhir:Device.udiCarrier [
     fhir:Identifier.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/identifier-type" ];
         fhir:Coding.code [ fhir:value "UDI" ]       ]     ];
     fhir:Identifier.system [ fhir:value "http://hl7.org/fhir/NamingSystem/fda-udi" ];
     fhir:Identifier.value [ fhir:value "{01}09504000059118{17}141120{10}7654321D{21}10987654d321" ]
  ];
  fhir:Device.status [ fhir:value "not-available"];
  fhir:Device.type [
     a sct:468063009;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://hl7.org/fhir/NamingSystem/gs1-di" ];
       fhir:Coding.code [ fhir:value "09504000059118" ]     ];
     fhir:CodeableConcept.coding [
       fhir:index 1;
       a sct:468063009;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "468063009" ];
       fhir:Coding.display [ fhir:value "Coated femoral stem prosthesis, modular" ]     ]
  ];
  fhir:Device.lotNumber [ fhir:value "7654321D"];
  fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc"];
  fhir:Device.expirationDate [ fhir:value "2014-11-20"^^xs:date];
  fhir:Device.model [ fhir:value "PM/Octane 2014"];
  fhir:Device.patient [
     fhir:reference <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ]
  ].

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.