This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R3
Implantable device/UDI example
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/sct/> .
@prefix xs: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir//Device/example-udi1> a fhir:Device;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "example-udi1"];
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ]
];
fhir:Device.identifier [
fhir:index 0;
fhir:Identifier.system [ fhir:value "http://acme.com/devices/pacemakers/octane/serial" ];
fhir:Identifier.value [ fhir:value "1234-5678-90AB-CDEF" ]
];
fhir:Device.identifier [
fhir:index 1;
fhir:Identifier.type [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/identifier-type" ];
fhir:Coding.code [ fhir:value "SNO" ] ] ];
fhir:Identifier.value [ fhir:value "10987654d321" ]
];
fhir:Device.udiCarrier [
fhir:Identifier.type [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/identifier-type" ];
fhir:Coding.code [ fhir:value "UDI" ] ] ];
fhir:Identifier.system [ fhir:value "http://hl7.org/fhir/NamingSystem/fda-udi" ];
fhir:Identifier.value [ fhir:value "{01}09504000059118{17}141120{10}7654321D{21}10987654d321" ]
];
fhir:Device.status [ fhir:value "not-available"];
fhir:Device.type [
a sct:468063009;
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/NamingSystem/gs1-di" ];
fhir:Coding.code [ fhir:value "09504000059118" ] ];
fhir:CodeableConcept.coding [
fhir:index 1;
a sct:468063009;
fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
fhir:Coding.code [ fhir:value "468063009" ];
fhir:Coding.display [ fhir:value "Coated femoral stem prosthesis, modular" ] ]
];
fhir:Device.lotNumber [ fhir:value "7654321D"];
fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc"];
fhir:Device.expirationDate [ fhir:value "2014-11-20"^^xs:date];
fhir:Device.model [ fhir:value "PM/Octane 2014"];
fhir:Device.patient [
fhir:reference <http://hl7.org/fhir/Patient/example>;
fhir:Reference.reference [ fhir:value "Patient/example" ]
].
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.