This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Definition for Value SetAudit Event ID
<ValueSet xmlns="http://hl7.org/fhir"> <id value="audit-event-type"/> <meta> <lastUpdated value="2015-12-11T17:38:40.294+11:00"/> <profile value="http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <h2>Audit Event ID</h2> <p>Event Types for Audit Events - defined by DICOM with some FHIR specific additions.</p> <p> <b>Copyright Statement:</b> These codes are excerpted from Digital Imaging and Communications in Medicine (DICOM) Standard, Part 16: Content Mapping Resource, Copyright © 2011 by the National Electrical Manufacturers Association. </p> <p>This value set has an inline code system http://hl7.org/fhir/audit-event-type, which defines the following codes:</p> <table class="codes"> <tr> <td> <b>Code</b> </td> <td> <b>Display</b> </td> <td> <b>Definition</b> </td> </tr> <tr> <td>rest <a name="rest"> </a> </td> <td>RESTful Operation</td> <td>Audit Event: Execution of a RESTful operation as defined by FHIR.</td> </tr> </table> <p>In addition, this value set includes codes from other code systems:</p> <ul> <li>Include these codes as defined in <a href="valueset-dicom-dcim.html">http://nema.org/dicom/dicm</a> <table> <tr> <td> <b>Code</b> </td> <td> <b>Display</b> </td> </tr> <tr> <td>110100</td> <td>Application Activity</td> <td>Audit event: Application Activity has taken place</td> </tr> <tr> <td>110101</td> <td>Audit Log Used</td> <td>Audit event: Audit Log has been used</td> </tr> <tr> <td>110102</td> <td>Begin Transferring DICOM Instances</td> <td>Audit event: Storage of DICOM Instances has begun</td> </tr> <tr> <td>110103</td> <td>DICOM Instances Accessed</td> <td>Audit event: DICOM Instances have been created, read, updated, or deleted</td> </tr> <tr> <td>110104</td> <td>DICOM Instances Transferred</td> <td>Audit event: Storage of DICOM Instances has been completed</td> </tr> <tr> <td>110105</td> <td>DICOM Study Deleted</td> <td>Audit event: Entire Study has been deleted</td> </tr> <tr> <td>110106</td> <td>Export</td> <td>Audit event: Data has been exported out of the system</td> </tr> <tr> <td>110107</td> <td>Import</td> <td>Audit event: Data has been imported into the system</td> </tr> <tr> <td>110108</td> <td>Network Entry</td> <td>Audit event: System has joined or left network</td> </tr> <tr> <td>110109</td> <td>Order Record</td> <td>Audit event: Order has been created, read, updated or deleted</td> </tr> <tr> <td>110110</td> <td>Patient Record</td> <td>Audit event: Patient Record has been created, read, updated, or deleted</td> </tr> <tr> <td>110111</td> <td>Procedure Record</td> <td>Audit event: Procedure Record has been created, read, updated, or deleted</td> </tr> <tr> <td>110112</td> <td>Query</td> <td>Audit event: Query has been made</td> </tr> <tr> <td>110113</td> <td>Security Alert</td> <td>Audit event: Security Alert has been raised</td> </tr> <tr> <td>110114</td> <td>User Authentication</td> <td>Audit event: User Authentication has been attempted</td> </tr> </table> </li> </ul> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/valueset-oid"> <valueUri value="urn:oid:2.16.840.1.113883.4.642.2.269"/> </extension> <url value="http://hl7.org/fhir/ValueSet/audit-event-type"/> <version value="20150326"/> <name value="Audit Event ID"/> <status value="active"/> <experimental value="true"/> <publisher value="NEMA/DICOM"/> <contact> <telecom> <system value="other"/> <value value="http://hl7.org/fhir"/> </telecom> <telecom> <system value="email"/> <value value="fhir@lists.hl7.org"/> </telecom> </contact> <date value="2015-03-26"/> <description value="Event Types for Audit Events - defined by DICOM with some FHIR specific additions."/> <copyright value="These codes are excerpted from Digital Imaging and Communications in Medicine (DICOM) Standard, Part 16: Content Mapping Resource, Copyright © 2011 by the National Electrical Manufacturers Association."/> <codeSystem> <extension url="http://hl7.org/fhir/StructureDefinition/valueset-oid"> <valueUri value="urn:oid:2.16.840.1.113883.4.642.1.269"/> </extension> <system value="http://hl7.org/fhir/audit-event-type"/> <caseSensitive value="true"/> <concept> <code value="rest"/> <display value="RESTful Operation"/> <definition value="Audit Event: Execution of a RESTful operation as defined by FHIR."/> </concept> </codeSystem> <compose> <include> <system value="http://nema.org/dicom/dicm"/> <concept> <code value="110100"/> </concept> <concept> <code value="110101"/> </concept> <concept> <code value="110102"/> </concept> <concept> <code value="110103"/> </concept> <concept> <code value="110104"/> </concept> <concept> <code value="110105"/> </concept> <concept> <code value="110106"/> </concept> <concept> <code value="110107"/> </concept> <concept> <code value="110108"/> </concept> <concept> <code value="110109"/> </concept> <concept> <code value="110110"/> </concept> <concept> <code value="110111"/> </concept> <concept> <code value="110112"/> </concept> <concept> <code value="110113"/> </concept> <concept> <code value="110114"/> </concept> </include> </compose> </ValueSet>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.