Connectathon 11 Snapshot

This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

V2-0357.json

Raw JSON (canonical form)

FHIR Value set/code system definition for HL7 v2 table 0357 ( Message Error Condition Codes)

{
  "resourceType": "ValueSet",
  "id": "v2-0357",
  "meta": {
    "profile": [
      "http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"
    ]
  },
  "text": {
    "status": "additional",
    "div": "<div>!-- Snipped for Brevity --></div>"
  },
  "url": "http://hl7.org/fhir/ValueSet/v2-0357",
  "version": "2.8.2",
  "name": "v2 Message Error Condition Codes",
  "status": "active",
  "experimental": true,
  "publisher": "HL7, Inc",
  "contact": [
    {
      "telecom": [
        {
          "system": "other",
          "value": "http://hl7.org"
        }
      ]
    }
  ],
  "description": "FHIR Value set/code system definition for HL7 v2 table 0357 ( Message Error Condition Codes)",
  "codeSystem": {
    "extension": [
      {
        "url": "http://hl7.org/fhir/StructureDefinition/valueset-oid",
        "valueUri": "urn:oid:2.16.840.1.133883.18.217"
      }
    ],
    "system": "http://hl7.org/fhir/v2/0357",
    "caseSensitive": false,
    "concept": [
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Success. Optional, as the AA conveys success. Used for systems that must always return a status code."
          }
        ],
        "code": "0",
        "display": "Message accepted",
        "designation": [
          {
            "language": "de",
            "value": "Nachricht akzeptiert"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Error: The message segments were not in the proper order, or required segments are missing."
          }
        ],
        "code": "100",
        "display": "Segment sequence error",
        "designation": [
          {
            "language": "de",
            "value": "Fehler in der Segmentreihenfolge"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Error: A required field is missing from a segment"
          }
        ],
        "code": "101",
        "display": "Required field missing",
        "designation": [
          {
            "language": "de",
            "value": "erforderliches Feld leer"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Error: The field contained data of the wrong data type, e.g. an NM field contained \"FOO\"."
          }
        ],
        "code": "102",
        "display": "Data type error",
        "designation": [
          {
            "language": "de",
            "value": "Datentypfehler"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Error: A field of data type ID or IS was compared against the corresponding table, and no match was found."
          }
        ],
        "code": "103",
        "display": "Table value not found",
        "designation": [
          {
            "language": "de",
            "value": "fehlender Eintrag in der Tabelle"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Error: a value exceeded the normative length, or the length that the application is able to safely handle."
          }
        ],
        "code": "104",
        "display": "Value too long"
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Rejection: The Message Type is not supported."
          }
        ],
        "code": "200",
        "display": "Unsupported message type",
        "designation": [
          {
            "language": "de",
            "value": "Nachrichtentyp wird nicht unterstützt"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Rejection: The Event Code is not supported."
          }
        ],
        "code": "201",
        "display": "Unsupported event code",
        "designation": [
          {
            "language": "de",
            "value": "Ereignis wird nicht unterstützt"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Rejection: The Processing ID is not supported."
          }
        ],
        "code": "202",
        "display": "Unsupported processing id",
        "designation": [
          {
            "language": "de",
            "value": "Processing-ID wird nicht unterstützt"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Rejection:  The Version ID is not supported."
          }
        ],
        "code": "203",
        "display": "Unsupported version id",
        "designation": [
          {
            "language": "de",
            "value": "Version wird nicht unterstützt"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Rejection: The ID of the patient, order, etc., was not found. Used for transactions other than additions, e.g. transfer of a non-existent patient."
          }
        ],
        "code": "204",
        "display": "Unknown key identifier",
        "designation": [
          {
            "language": "de",
            "value": "Schlüsselwert nicht gefunden"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Rejection: The ID of the patient, order, etc., already exists. Used in response to addition transactions (Admit, New Order, etc.)."
          }
        ],
        "code": "205",
        "display": "Duplicate key identifier",
        "designation": [
          {
            "language": "de",
            "value": "doppelter Schlüsselwert"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Rejection: The transaction could not be performed at the application storage level, e.g. database locked."
          }
        ],
        "code": "206",
        "display": "Application record locked",
        "designation": [
          {
            "language": "de",
            "value": "Datensatz durch Applikation gesperrt"
          }
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
            "valueString": "Rejection: A catchall for internal errors not explicitly covered by other codes."
          }
        ],
        "code": "207",
        "display": "Application internal error",
        "designation": [
          {
            "language": "de",
            "value": "applikationsinterner Fehler"
          }
        ]
      }
    ]
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.