This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
FHIR Value set/code system definition for HL7 v2 table 0174 ( Nature of Service/Test/Observation)
<ValueSet xmlns="http://hl7.org/fhir"> <id value="v2-0174"/> <meta> <profile value="http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"/> </meta> <text> <status value="additional"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p>Nature of Service/Test/Observation</p> <table class="grid"> <tr> <td> <b>Code</b> </td> <td> <b>Description</b> </td> <td> <b>Deutsch (German)</b> </td> <td> <b>Nederlands (Dutch)</b> </td> <td> <b>Comment</b> </td> <td> <b>Version</b> </td> </tr> <tr> <td>A <a name="A"> </a> </td> <td>Atomic service/test/observation (test code or treatment code)</td> <td>Einzeluntersuchung</td> <td>Atomische service/test/observatie (testcode of behandelingcode)</td> <td>can be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segments</td> <td>added v2.2</td> </tr> <tr> <td>C <a name="C"> </a> </td> <td>Single observation calculated via a rule or formula from other independent observations (e.g. Alveolar-arterial ratio, cardiac output)</td> <td>Berechnetes Einzelergebnis</td> <td>Enkelvoudige observatie berekend via regels of formule uit andere onafhankelijke observaties (bijv. Alveolair--arteriële gradiënt, hart-minuut-volume)</td> <td>can be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segment</td> <td>added v2.2</td> </tr> <tr> <td>F <a name="F"> </a> </td> <td>Functional procedure that may consist of one or more interrelated measures (e.g. glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens</td> <td>Funktionstest</td> <td>Functionele procedure die kan bestaan uit een of meer gerelateerde metingen (bijv. glucosetolerantie test, creatinineklaring), meestal uitgevoerd op verschillende momenten en/of verschillende monsters</td> <td>can be associated with one or more OM4 (specimen) segments<p>See comment for value S</td> <td>added v2.2</td> </tr> <tr> <td>P <a name="P"> </a> </td> <td>Profile or battery consisting of many independent atomic observations (e.g. SMA12, electrolytes), usually done at one instrument on one specimen</td> <td>Batterieanordnung</td> <td>Profiel of battery bestaande uit vele onafhankelijke atomische observaties (bijv. SMA12, electrolyten), meestal met één instrument op één monster</td> <td>can be associated with one or more OM4 (specimen) segments<p>See comment for value S</td> <td>added v2.2</td> </tr> <tr> <td>S <a name="S"> </a> </td> <td>Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g. routines = CBC, UA, electrolytes)<p>This set indicates that the code being described is used to order multiple service/test/observation b</td> <td>Latte von mehreren Batterieanforderungen (Aufnahmelatte)</td> <td>Superset--een set batteries of procedures aangevraagd onder een enkele aanvraagcode maar behandeld als afzonderlijke batteries (bijv. routines = CBC, UA, electrolyten); Deze set geeft aan dat de bedoelde code wordt gebruikt voor het aanvragen van meerdere services/tests/observa ties</td> <td>can be associated with one or more OM4 (specimen) segments<p>Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in o</td> <td>added v2.2</td> </tr> </table> </div> </text> <url value="http://hl7.org/fhir/ValueSet/v2-0174"/> <version value="2.8.2"/> <name value="v2 Nature of Service/Test/Observation"/> <status value="active"/> <experimental value="true"/> <publisher value="HL7, Inc"/> <contact> <telecom> <system value="other"/> <value value="http://hl7.org"/> </telecom> </contact> <description value="FHIR Value set/code system definition for HL7 v2 table 0174 ( Nature of Service/Test/Observation)"/> <codeSystem> <extension url="http://hl7.org/fhir/StructureDefinition/valueset-oid"> <valueUri value="urn:oid:2.16.840.1.133883.18.90"/> </extension> <system value="http://hl7.org/fhir/v2/0174"/> <caseSensitive value="false"/> <concept> <extension url="http://hl7.org/fhir/StructureDefinition/valueset-comments"> <valueString value="can be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segments"/> </extension> <code value="A"/> <display value="Atomic service/test/observation (test code or treatment code)"/> <designation> <language value="de"/> <value value="Einzeluntersuchung"/> </designation> <designation> <language value="nl"/> <value value="Atomische service/test/observatie (testcode of behandelingcode)"/> </designation> </concept> <concept> <extension url="http://hl7.org/fhir/StructureDefinition/valueset-comments"> <valueString value="can be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segment"/> </extension> <code value="C"/> <display value="Single observation calculated via a rule or formula from other independent observations (e.g. Alveolar-arterial ratio, cardiac output)"/> <designation> <language value="de"/> <value value="Berechnetes Einzelergebnis"/> </designation> <designation> <language value="nl"/> <value value="Enkelvoudige observatie berekend via regels of formule uit andere onafhankelijke observaties (bijv. Alveolair--arteriële gradiënt, hart-minuut-volume)"/> </designation> </concept> <concept> <extension url="http://hl7.org/fhir/StructureDefinition/valueset-comments"> <valueString value="can be associated with one or more OM4 (specimen) segments<p>See comment for value S"/> </extension> <code value="F"/> <display value="Functional procedure that may consist of one or more interrelated measures (e.g. glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens"/> <designation> <language value="de"/> <value value="Funktionstest"/> </designation> <designation> <language value="nl"/> <value value="Functionele procedure die kan bestaan uit een of meer gerelateerde metingen (bijv. glucosetolerantie test, creatinineklaring), meestal uitgevoerd op verschillende momenten en/of verschillende monsters"/> </designation> </concept> <concept> <extension url="http://hl7.org/fhir/StructureDefinition/valueset-comments"> <valueString value="can be associated with one or more OM4 (specimen) segments<p>See comment for value S"/> </extension> <code value="P"/> <display value="Profile or battery consisting of many independent atomic observations (e.g. SMA12, electrolytes), usually done at one instrument on one specimen"/> <designation> <language value="de"/> <value value="Batterieanordnung"/> </designation> <designation> <language value="nl"/> <value value="Profiel of battery bestaande uit vele onafhankelijke atomische observaties (bijv. SMA12, electrolyten), meestal met één instrument op één monster"/> </designation> </concept> <concept> <extension url="http://hl7.org/fhir/StructureDefinition/valueset-comments"> <valueString value="can be associated with one or more OM4 (specimen) segments<p>Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in o"/> </extension> <code value="S"/> <display value="Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g. routines = CBC, UA, electrolytes)<p>This set indicates that the code being described is used to order multiple service/test/observation b"/> <designation> <language value="de"/> <value value="Latte von mehreren Batterieanforderungen (Aufnahmelatte)"/> </designation> <designation> <language value="nl"/> <value value="Superset--een set batteries of procedures aangevraagd onder een enkele aanvraagcode maar behandeld als afzonderlijke batteries (bijv. routines = CBC, UA, electrolyten); Deze set geeft aan dat de bedoelde code wordt gebruikt voor het aanvragen van meerdere services/tests/observa ties"/> </designation> </concept> </codeSystem> </ValueSet>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.