1.25.3.1.78 HL7 Version 2 Table 0078

This is a table defined as part of HL7 v2 . Related FHIR content: v2 Interpretation Codes.

Summary

Defining URL:http://hl7.org/fhir/ValueSet/v2-0078
Name:v2 Interpretation Codes
Definition:FHIR Value set/code system definition for HL7 v2 table 0078 ( Interpretation Codes)
OID:??
System URL:http://hl7.org/fhir/v2/0078
System OID:2.16.840.1.133883.18.31
Source ResourceXML / JSON

This value set is not currently used

1.25.3.1.78.1 Content Logical Definition

Interpretation Codes

CodeDescriptionDeutsch (German)Nederlands (Dutch)CommentVersion
< Off scale lowUnter Meßbereich (Extremwertverletzung)Onder absolute ondergrens instrumentschaalThe result is below the minimum detection limit (the test procedure or equipment is the limiting factor).<p>Synonyms: Below analytical limit, low off scalefrom v2.1
> Off scale highÜber Meßbereich (Extremwertverletzung)Boven absolute bovengrens instrumentschaalThe result is above the maximum quantifiable limit (the test procedure or equipment is the limiting factor).<p>Synonyms: Above analytical limit, high off scaleadded v2.2
A Abnormalanormal (nicht numerisch)AbnormaalThe result or observation value is outside the reference range or expected norm (as defined for the respective test procedure).<p>Note: Typically applies to non-numeric results.from v2.1
AA Critically abnormalPathologisch (nicht numerisch)Kritiek abnormaalThe result or observation value is outside a reference range or expected norm at a level at which immediate action should be considered for patient safety (as defined for the respective test procedure).<p>[Note: Typically applies to non-numeric results. from v2.1
AC Anti-complementary substances presentAnti-complementaire stoffen aanwezigDeprecatedadded v2.7
B BetterVerbesserungBeterThe current result or observation value has improved compared to the previous result or observation value (the change is significant as defined in the respective test procedure).<p>Note: This can be applied to quantitative or qualitative observations.added v2.2
D Significant change downDeutlicher Trend nach untenSignificante wijzging omlaagThe current result has decreased from the previous result for a quantitative observation (the change is significant as defined in the respective test procedure).from v2.1
DET DetectedGedetecteerdThe measurement of the specified component / analyte, organism or clinical sign above the limit of detection of the performed test or procedure.added v2.7
H HighOberhalb oberer Grenze ReferenzbereichHoogThe result for a quantitative observation is above the upper limit of the reference range (as defined for the respective test procedure).<p>Synonym: Above high normalfrom v2.1
HH Critically highOberhalb oberer pathologischer GrenzeKritiek hoogThe result for a quantitative observation is above a reference level at which immediate action should be considered for patient safety (as defined for the respective test procedure).<p>Synonym: Above upper panic limitsfrom v2.1
HM Hold for Medical ReviewVastgehouden voor medische reviewDeprecatedadded v2.8
HU Very highZeer hoogSignificantly high: A test result that is significantly higher than the reference (normal) or therapeutic interval, but has not reached the critically high value and might need special attention, as defined by the laboratory or the clinician.<p>Note:added v2.8.2
I IntermediateIntermediärGemiddeldBacterial strain inhibited in vitro by a<p>concentration of an antimicrobial agent that is associated with<p>uncertain therapeutic effect.<p>Reference: CLSI (http://www.clsi.org/Content/NavigationMenu/Resources/HarmonizedTerminologyDatabase/Harmonized_Terfrom v2.1
IE Insufficient evidenceOnvoldoende bewijsThere is insufficient evidence that the species in question is a good target for therapy with the drug. A categorical interpretation is not possible.<p>Reference: EUCAST<p>Note: A MIC with "IE" and/or a comment may be reported (without an accompanying S,added v2.8.2
IND IndeterminateOnbepaaldThe specified component / analyte, organism or clinical sign could neither be declared positive / negative or detected / not detected by the performed test or procedure.added v2.7
L LowUnterhalb unterer Grenze ReferenzbereichLaagThe result for a quantitative observation is below the lower limit of the reference range (as defined for the respective test procedure).<p>Synonym: Below low normaladded v2.2
LL Critically lowUnterhalb unterer pathologischer GrenzeKritiek laagThe result for a quantitative observation is below a reference level at which immediate action should be considered for patient safety (as defined for the respective test procedure).<p>Synonym: Below lower panic limitsfrom v2.1
LU Very lowZeer laagSignificantly low: A test result that is significantly lower than the reference (normal) or therapeutic interval, but has not reached the critically low value and might need special attention, as defined by the laboratory or the clinician.<p>Note: Tadded v2.8.2
MS Moderately susceptible. Indicates for microbiology susceptibilities only.mäßig empfindlichGemiddeld gevoelig. Alleen voor microbiologische gevoeligheid.Deprecated - CLSI now only supports S, I & R. This information can be found in CLSI document M100-S22; Vol. 32 No.3; CLSI Performance<p>Standards for Antimicrobial Susceptibility Testing; Twenty-Second Informational Supplement. Jan 2012.from v2.1
N NormalNormal (nicht numerisch)NormaalThe result or observation value is within the reference range or expected norm (as defined for the respective test procedure).<p>Note: Applies to numeric or non-numeric results.added v2.2
ND Not DetectedNiet-gedetecteerdThe presence of the specified component / analyte, organism or clinical sign could not be determined within the limit of detection of the performed test or procedure.added v2.7
NEG NegativeNegatiefAn absence finding of the specified component / analyte, organism or clinical sign based on the established threshold of the performed test or procedure.<p>Note: Negative does not necessarily imply the complete absence of the specified item.added v2.7
NR Non-reactiveNiet-reactiefAn absence finding used to indicate that the specified component / analyte did not react measurably with the reagent.added v2.7
NS Non-susceptibleNiet-gevoeligA category used for isolates for which only a susceptible interpretive criterion has been designated because of the absence or rare occurrence of resistant strains. Isolates that have MICs above or zone diameters below the value indicated for the susceptiadded v2.8.2
OBX Interpretation qualifiers in separate OBX segmentsInterpretatie qualifiers in afzonderlijke OBX-segmentenDeprecatedadded v2.8
POS PositivePositiefA presence finding of the specified component / analyte, organism or clinical sign based on the established threshold of the performed test or procedure.added v2.7
QCF Quality Control FailureKwaliteitscontrole foutDeprecatedadded v2.7
R ResistantResistentResistentBacterial strain inhibited in vitro by a concentration of an antimicrobial agent that is associated with a high likelihood of therapeutic failure.<p>Reference: CLSI (http://www.clsi.org/Content/NavigationMenu/Resources/HarmonizedTerminologyDatabase/Harmonfrom v2.1
RR ReactiveReactiefA presence finding used to indicate that the specified component / analyte reacted with the reagent above the reliably measurable limit of the performed test.added v2.7
S SusceptibleEmpfindlichGevoeligBacterial strain inhibited by in vitro concentration of an antimicrobial agent that is associated with a high likelihood of therapeutic success.<p>Reference: CLSI (http://www.clsi.org/Content/NavigationMenu/Resources/HarmonizedTerminologyDatabase/Harmonizfrom v2.1
SDD Susceptible-dose dependentGevoelig dosis-afhankelijkA category that includes isolates with antimicrobial agent minimum inhibitory concentrations (MICs) that approach usually attainable blood and tissue levels and for which response rates may be lower than for susceptible isolates.<p>Reference: CLSI documenadded v2.8.2
SYN-R Synergy - resistantSynergie - resistentA category for isolates where the bacteria (e.g. enterococci) are not susceptible in vitro to a combination therapy (e.g. high-level aminoglycoside and cell wall active agent). This is predictive that this combination therapy will not be effective.<p>Usaadded v2.8.2
SYN-S Synergy - susceptibleSynergie - gevoeligA category for isolates where the bacteria (e.g. enterococci) are susceptible in vitro to a combination therapy (e.g. high-level aminoglycoside and cell wall active agent). This is predictive that this combination therapy will be effective.<p>Usage Note:added v2.8.2
TOX Cytotoxic substance presentCytotoxische stoffen aanwezigDeprecatedadded v2.7
U Significant change upDeutlicher Trend nach obenSignificante wijzging omhoogThe current result has increased from the previous result for a quantitative observation (the change is significant as defined in the respective test procedure).from v2.1
VS Very susceptible. Indicates for microbiology susceptibilities only.Sehr empfindlichZeer gevoelig. Alleen voor microbiologische gevoeligheid.Deprecated - CLSI now only supports S, I & R. This information can be found in CLSI document M100-S22; Vol. 32 No.3; CLSI Performance<p>Standards for Antimicrobial Susceptibility Testing; Twenty-Second Informational Supplement. Jan 2012.from v2.1
W WorseVerschlechterungSlechterThe current result or observation value has degraded compared to the previous result or observation value (the change is significant as defined in the respective test procedure).<p>Note: This can be applied to quantitative or qualitative observations.added v2.2
WR Weakly reactiveZwak reactiefA weighted presence finding used to indicate that the specified component / analyte reacted with the reagent, but below the reliably measurable limit of the performed test.added v2.7
null No range defined, or normal ranges don't applyKein Referenzbereich / Referenzbereich nicht anwendbarGeen referentiewaarden gedefinieerd of normale waarden niet van toepassingDeprecatedfrom v2.1