Connectathon 11 Snapshot

This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Questionnaire-example-gcs

This is the narrative for the resource. See also the XML or JSON format.


Generated Narrative with Details

id: gcs

contained: , ,

status: draft

date: 03/08/2015

publisher: FHIR Project team

title: Glasgow Coma Score

concept: Glasgow coma score total (Details: LOINC code 9269-2 = 'Glasgow coma score total', stated as 'null')

subjectType: Patient

item

linkId: 1.1

concept: Glasgow coma score verbal (Details: LOINC code 9270-0 = 'Glasgow coma score verbal', stated as 'null')

type: choice

options: id: verbal; http://loinc.org/ValueSet/LL356-7; name: GCS Verbal Value Set; status: active; description: LOINC ANSWER LIST (LL356-7)

item

linkId: 1.2

concept: Glasgow coma score motor (Details: LOINC code 9268-4 = 'Glasgow coma score motor', stated as 'null')

type: choice

options: id: motor; http://loinc.org/ValueSet/LL357-5; name: GCS Motor Value Set; status: active; description: LOINC ANSWER LIST (LL357-5)

item

linkId: 1.3

concept: Glasgow coma score eye opening (Details: LOINC code 9267-6 = 'Glasgow coma score eye opening', stated as 'null')

type: choice

options: id: eye; http://loinc.org/ValueSet/LL355-9; name: GCS Eye Value Set; status: active; description: LOINC ANSWER LIST (LL355-9)


 

Other examples that reference this example:

  • QuestionnaireResponse/Glasgow Coma Score
  •  

    Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.