Connectathon 11 Snapshot

This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Specimen-example.xml

Raw XML (canonical form)

Example of QICore Specimen (id = "specimen-example")

<Specimen xmlns="http://hl7.org/fhir">
 <id value="specimen-example"/>
  <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: specimen-example</p><p><b>type</b>: Venous blood specimen <span>(Details : {SNOMED CT code '122555007' = '122555007', given as 'Venous blood specimen'})</span></p><p><b>subject</b>: <a>Peter Patient</a></p><p><b>receivedTime</b>: 04/03/2011 6:03:00 PM</p><h3>Collections</h3><table><tr><td>-</td><td><b>Extension</b></td><td><b>Collected[x]</b></td><td><b>Quantity</b></td></tr><tr><td>*</td><td>Extensions: Todo</td><td>06/03/2011 5:15:00 PM</td><td>6 mL</td></tr></table><h3>Treatments</h3><table><tr><td>-</td><td><b>Extension</b></td><td><b>Description</b></td><td><b>Additive</b></td></tr><tr><td>*</td><td>Extensions: Todo</td><td>Treated with anticoagulants.</td><td><a>Substance/example</a></td></tr></table><h3>Containers</h3><table><tr><td>-</td><td><b>Extension</b></td><td><b>Type</b></td><td><b>Capacity</b></td></tr><tr><td>*</td><td>Extensions: Todo</td><td>Specimen vial <span>(Details : {SNOMED CT code '434746001' = '434746001', given as 'Specimen vial'})</span></td><td>10 mL</td></tr></table></div></text><type>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="122555007"/>
      <display value="Venous blood specimen"/>
    </coding>
  </type>

  <subject>
    <reference value="Patient/example"/>
    <display value="Peter Patient"/>
  </subject>

  <receivedTime value="2011-03-04T07:03:00Z"/>

  <collection>
    <extension url="http://hl7.org/fhir/StructureDefinition/specimen-collectionPriority">
      <valueCodeableConcept>
        <coding>
          <system value="http://example.com"/>
          <code value="5"/>
          <display value="ROUTINE"/>
        </coding>
      </valueCodeableConcept>
    </extension>
    <extension url="http://hl7.org/fhir/StructureDefinition/specimen-specialHandling">
      <valueCodeableConcept>
        <coding>
          <system value="http://hl7.org/fhir/v3/ActCode"/>
          <code value="NOPERSISTP"/>
          <display value="no collection beyond purpose of use"/>
        </coding>
      </valueCodeableConcept>
    </extension>
    <collectedDateTime value="2011-03-06T06:15:00Z"/>
    <quantity>
      <extension url="http://hl7.org/fhir/StructureDefinition/specimen-isDryWeight">
        <valueBoolean value="false"/>
      </extension>
      <value value="6"/>
      <unit value="mL"/>
    </quantity>
  </collection>
  <treatment>
    <extension url="http://hl7.org/fhir/StructureDefinition/specimen-treatmentTime">
      <valuePeriod>
        <start value="2011-03-04T07:03:00Z"/>
        <end value="2011-03-04T07:03:00Z"/>
      </valuePeriod>
    </extension>
    <description value="Treated with anticoagulants."/>
    <additive>
      <reference value="Substance/example"/>
    </additive>
  </treatment>
  <container>
    <extension url="http://hl7.org/fhir/StructureDefinition/specimen-sequenceNumber">
      <valueInteger value="1"/>
    </extension>
    <type>
      <coding>
        <system value="http://snomed.info/sct"/>
        <code value="434746001"/>
        <display value="Specimen vial"/>
      </coding>
    </type>
    <capacity>
      <value value="10"/>
      <unit value="mL"/>
    </capacity>

  </container>
</Specimen>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.