Connectathon 11 Snapshot

This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4B R4 R3 R2

Media-example-dicom.xml

Raw XML (canonical form)

Example Ultrasound Image (id = "1.2.840.11361907579238403408700.3.0.14.19970327150033")

<Media xmlns="http://hl7.org/fhir">
  <id value="1.2.840.11361907579238403408700.3.0.14.19970327150033"/>
  
  <!--  
    This example demonstrates how to represent an image 
    originally sourced by a DICOM acquisition device
    as a Media resource. Whether this is appropriate depends
    on the complexity of the image - the media resource only
    contains crude metadata, and plain png/jpg (typically)
    pixels. This is suitable for the bulk of simple images
    shared as summaries with consumers, but not at all suitable 
    for other kinds of images, or for internal radiology 
    reporting usage    
    -->
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
      Ultrasound Image on patient &quot;James Chalmers&quot;:<br/>
      <img alt="WADO reference to image" src="http://imaging.acme.com/wado/server?requestType=WADO&amp;contentType=application%2Fdicom&amp;studyUi
      d=1.2.840.113619.2.21.848.34082.0.538976288.3&amp;seriesUid=1.2.840.113619.2.21.3408.700.0.757923840.
      3.0&amp;objectUid=1.2.840.11361907579238403408700.3.0.14.19970327150033"/>
        
    </div>
  </text>

  <!--   
    this is added to demonstrate the use of DICOM extensions.
    0002,0010 is the DICOM transfer syntax of the referenced image
     -->
  <extension url="http://nema.org/fhir/extensions#0002-0010">
    <valueUri value="urn:oid:1.2.840.10008.1.2.1"/>
  </extension>  

  <type value="photo"/>

  <subtype>
    <coding>
      <system value="http://nema.org/dicom/dicm"/>
      <code value="US"/>
    </coding>
  </subtype>

  <identifier>
    <use value="official"/>
    <type><text value="InstanceUID"/></type>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:1.2.840.11361907579238403408700.3.0.14.19970327150033"/>
  </identifier> 
  <identifier>
    <type><text value="accessionNo"/></type>
    <!--   the imaging department accession number. (they recycle numbers each year)   -->    
    <system value="http://acme-imaging.com/accession/2012"/>
    <value value="1234567"/>
 </identifier>
  <identifier>
    <type><text value="studyId"/></type>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:1.2.840.113619.2.21.848.34082.0.538976288.3"/>
  </identifier>
  <identifier>
    <type><text value="seriesId"/></type>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:1.2.840.113619.2.21.3408.700.0.757923840.3.0"/>
  </identifier>  

  <subject>
    <reference value="Patient/example"/>
  </subject>
 
  <view>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="399067008"/>
      <display value="Lateral projection"/>
    </coding>
  </view>
  
  
  <deviceName value="G.E. Medical Systems"/>
  <height value="480"/>
  <width value="640"/>
  
  <!--   and a reference to the image data   -->
  <content>
    <contentType value="application/dicom"/>
    <!--   The actual image could be anywhere. This is a WADO example   -->
    <url value="http://imaging.acme.com/wado/server?requestType=WADO&amp;contentType=application%2Fdicom&amp;studyUi
    d=1.2.840.113619.2.21.848.34082.0.538976288.3&amp;seriesUid=1.2.840.113619.2.21.3408.700.0.757923840.
    3.0&amp;objectUid=1.2.840.11361907579238403408700.3.0.14.19970327150033"/>
  </content>

</Media>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.