Connectathon 11 Snapshot

This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Encounter-example-f002-lung.json

Raw JSON (canonical form)

Real-world encounter example

{
  "resourceType": "Encounter",
  "id": "f002",
  "text": {
    "status": "generated",
    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f002</p><p><b>identifier</b>: v3251 (OFFICIAL)</p><p><b>status</b>: finished</p><p><b>class</b>: outpatient</p><p><b>type</b>: Patient-initiated encounter <span>(Details : {SNOMED CT code '270427003' = '270427003', given as 'Patient-initiated encounter'})</span></p><p><b>priority</b>: Urgent <span>(Details : {SNOMED CT code '103391001' = '103391001', given as 'Urgent'})</span></p><p><b>patient</b>: <a>P. van de Heuvel</a></p><h3>Participants</h3><table><tr><td>-</td><td><b>Individual</b></td></tr><tr><td>*</td><td><a>M.I.M Versteegh</a></td></tr></table><p><b>length</b>: 140 min<span> (Details: http://unitsofmeasure.org code min = '??')</span></p><p><b>reason</b>: Partial lobectomy of lung <span>(Details : {SNOMED CT code '34068001' = '34068001', given as 'Partial lobectomy of lung'})</span></p><h3>Hospitalizations</h3><table><tr><td>-</td><td><b>PreAdmissionIdentifier</b></td><td><b>AdmitSource</b></td><td><b>DischargeDisposition</b></td></tr><tr><td>*</td><td>98682 (OFFICIAL)</td><td>Referral by radiologist <span>(Details : {SNOMED CT code '305997006' = '305997006', given as 'Referral by radiologist'})</span></td><td>Discharge to home <span>(Details : {SNOMED CT code '306689006' = '306689006', given as 'Discharge to home'})</span></td></tr></table><p><b>serviceProvider</b>: <a>BMC</a></p></div>"
  },
  "identifier": [
    {
      "use": "official",
      "system": "http://www.bmc.nl/zorgportal/identifiers/encounters",
      "value": "v3251"
    }
  ],
  "status": "finished",
  "class": "outpatient",
  "type": [
    {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "270427003",
          "display": "Patient-initiated encounter"
        }
      ]
    }
  ],
  "priority": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "103391001",
        "display": "Urgent"
      }
    ]
  },
  "patient": {
    "reference": "Patient/f001",
    "display": "P. van de Heuvel"
  },
  "participant": [
    {
      "individual": {
        "reference": "Practitioner/f003",
        "display": "M.I.M Versteegh"
      }
    }
  ],
  "length": {
    "value": 140,
    "unit": "min",
    "system": "http://unitsofmeasure.org",
    "code": "min"
  },
  "reason": [
    {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "34068001",
          "display": "Partial lobectomy of lung"
        }
      ]
    }
  ],
  "hospitalization": {
    "preAdmissionIdentifier": {
      "use": "official",
      "system": "http://www.bmc.nl/zorgportal/identifiers/pre-admissions",
      "value": "98682"
    },
    "admitSource": {
      "fhir_comments": [
        "      <preAdmissionTest>\n            <coding>\n                <system value=\"http://snomed.info/sct\"/>\n                <code value=\"399208008\"/>\n                <display value=\"Chest X-ray\"/>\n            </coding>\n            <coding>\n                <system value=\"http://snomed.info/sct\"/>\n                <code value=\"396550006\"/>\n                <display value=\"Blood test\"/>\n            </coding>\n        </preAdmissionTest>   "
      ],
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "305997006",
          "display": "Referral by radiologist"
        }
      ]
    },
    "dischargeDisposition": {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "306689006",
          "display": "Discharge to home"
        }
      ]
    }
  },
  "serviceProvider": {
    "reference": "Organization/f001",
    "display": "BMC"
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.