This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
Lipid Panel Order
{ "resourceType": "DiagnosticOrder", "id": "example", "text": { "status": "generated", "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>contained</b>: </p><p><b>subject</b>: <a>Patient/example</a></p><p><b>orderer</b>: <a>Practitioner/example</a></p><p><b>identifier</b>: Placer = 2345234234234</p><p><b>encounter</b>: <a>Encounter/example</a></p><p><b>reason</b>: Fam hx-ischem heart dis <span>(Details : {ICD-9 code 'V173' = '??', given as 'Fam hx-ischem heart dis'})</span></p><p><b>supportingInformation</b>: id: fasting; status: final; Fasting status - Reported <span>(Details : {LOINC code '49541-6' = 'Fasting status - Reported', given as 'Fasting status - Reported'})</span>; Patient/example; Yes <span>(Details : {http://hl7.org/fhir/v2/0136 code 'Y' = 'Yes', given as 'Yes'})</span></p><p><b>status</b>: received</p><h3>Events</h3><table><tr><td>-</td><td><b>Status</b></td><td><b>DateTime</b></td><td><b>Actor</b></td></tr><tr><td>*</td><td>requested</td><td>02/05/2013 4:16:00 PM</td><td><a>Practitioner/example</a></td></tr></table><h3>Items</h3><table><tr><td>-</td><td><b>Code</b></td><td><b>Specimen</b></td></tr><tr><td>*</td><td>Lipid Panel <span>(Details : {http://acme.org/tests code 'LIPID' = '??)</span></td><td><a>Specimen/101</a></td></tr></table><p><b>note</b>: patient is afraid of needles</p></div>" }, "contained": [ { "resourceType": "Observation", "id": "fasting", "status": "final", "_status": { "fhir_comments": [ " the mandatory quality flag: " ] }, "code": { "coding": [ { "system": "http://loinc.org", "code": "49541-6", "display": "Fasting status - Reported" } ] }, "subject": { "reference": "Patient/example" }, "valueCodeableConcept": { "coding": [ { "system": "http://hl7.org/fhir/v2/0136", "code": "Y", "display": "Yes" } ] } } ], "subject": { "reference": "Patient/example" }, "orderer": { "reference": "Practitioner/example" }, "identifier": [ { "type": { "coding": [ { "system": "http://hl7.org/fhir/identifier-type", "code": "PLAC" } ], "text": "Placer" }, "system": "urn:oid:1.3.4.5.6.7", "value": "2345234234234" } ], "encounter": { "reference": "Encounter/example" }, "reason": [ { "coding": [ { "system": "http://hl7.org/fhir/sid/icd-9", "code": "V173", "display": "Fam hx-ischem heart dis" } ] } ], "supportingInformation": [ { "reference": "#fasting" } ], "status": "received", "event": [ { "status": "requested", "dateTime": "2013-05-02T16:16:00-07:00", "actor": { "reference": "Practitioner/example" } } ], "item": [ { "code": { "coding": [ { "system": "http://acme.org/tests", "code": "LIPID" } ], "text": "Lipid Panel" }, "specimen": [ { "reference": "Specimen/101" } ] } ], "note": [ { "text": "patient is afraid of needles" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.