This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R3 R2
General DeviceComponent example (id = "example")
<DeviceComponent xmlns="http://hl7.org/fhir"> <!-- <Simple_MDS xmlns:xsd="http://www.w3.org/2001/XMLSchema-instance" xsd:noNamespaceSchemaLocation="D IM.xsd" Handle="0" System-Id="ID 13.1" Mds-Status="disconnected" object_id="MDC_MOC_VMS_MDS_SIMP" Class="MDC_MOC_VMS_MDS_SIMP"> <Nomenclature-Version object_id="MDC_ATTR_NOM_VERS" nom-minor-version="0"> <nom-major-version majorVersion1="true"/> </Nomenclature-Version> <System-Model object_id="MDC_ATTR_ID_MODEL" manufacturer="Center4MI" model-number="2-0-14"/> <System-Type object_id="MDC_ATTR_SYS_TYPE" partition="nom-part-obj" code="MDC_DEV_ANALY_SAT_O2_MD S"/> <Locale object_id="MDC_ATTR_LOCALE" charset="ISO-10646-UCS-2" country="US" Language="en"/> <VMD Handle="20" object_id="MDC_MOC_VMO_VMD" Class="MDC_MOC_VMO_VMD"> <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-obj" code="MDC_DEV_ANALY_SAT_O2_VMD"/> <VMD-Status vmd-standby="true"/> <Channel Handle="22" object_id="MDC_MOC_VMO_CHAN" Class="MDC_MOC_VMO_CHAN" Physical-Channel-No=" 1" Logical-Channel-No="1" Channel-Id="MDC_DEV_ANALY_SAT_O2_CHAN"> <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-obj" code="MDC_DEV_ANALY_SAT_O2_CHAN"/> <Channel-Status chan-standby="true"/> <Numeric Handle="221" object_id="MDC_MOC_VMO_METRIC_NU" Class="MDC_MOC_VMO_METRIC_NU" Nu-Measure-Resolution="0" Metric-Id="MDC_PULS_OXIM_SAT_O2"> <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-metric" code="MDC_PULS_OXIM_SAT_O2"/> <Metric-Specification object_id="MDC_ATTR_METRIC_SPECN" update-period="8192" category="auto-me asurement"> <relevance rv-unspec="true"/> <access upd-periodic="true" acc-scan="true" sc-opt-normal="true"/> <structure object_id="NA1" ms-comp-no="0" ms-struct="simple"/> </Metric-Specification> <Nu-Observed-Value object_id="MDC_ATTR_NU_VAL_OBS" value="0" unit-code="MDC_DIM_PERCENT" metric-id="MDC_PULS_OXIM_SAT_O2"> <state not-available="true"/> </Nu-Observed-Value> </Numeric> <Numeric Handle="222" object_id="MDC_MOC_VMO_METRIC_NU" Class="MDC_MOC_VMO_METRIC_NU" Nu-Measure-Resolution="0" Metric-Id="MDC_BLD_PERF_INDEX"> <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-metric" code="MDC_BLD_PERF_INDEX"/> <Metric-Specification object_id="MDC_ATTR_METRIC_SPECN" update-period="8192" category="auto-me asurement"> <relevance rv-unspec="true"/> <access upd-periodic="true" acc-scan="true" sc-opt-normal="true"/> <structure object_id="NA1" ms-comp-no="0" ms-struct="simple"/> </Metric-Specification> <Nu-Observed-Value object_id="MDC_ATTR_NU_VAL_OBS" value="0" unit-code="MDC_DIM_MILLI_L_PER_MI N" metric-id="MDC_BLD_PERF_INDEX"> <state not-available="true"/> </Nu-Observed-Value> </Numeric> </Channel> <Channel Handle="33" object_id="MDC_MOC_VMO_CHAN" Class="MDC_MOC_VMO_CHAN" Physical-Channel-No=" 2" Logical-Channel-No="2" Channel-Id="MDC_DEV_PULS_CHAN"> <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-obj" code="MDC_DEV_PULS_CHAN"/> <Channel-Status chan-standby="true"/> <Numeric Handle="333" object_id="MDC_MOC_VMO_METRIC_NU" Class="MDC_MOC_VMO_METRIC_NU" Nu-Measure-Resolution="0" Metric-Id="MDC_PULS_OXIM_PULS_RATE"> <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-metric" code="MDC_PULS_OXIM_PULS_RATE"/ > <Metric-Specification object_id="MDC_ATTR_METRIC_SPECN" update-period="8192" category="auto-me asurement"> <relevance rv-unspec="true"/> <access upd-periodic="true" acc-scan="true" sc-opt-normal="true"/> <structure object_id="NA1" ms-comp-no="0" ms-struct="simple"/> </Metric-Specification> <Nu-Observed-Value object_id="MDC_ATTR_NU_VAL_OBS" value="0" unit-code="MDC_DIM_BEAT_PER_MIN" metric-id="MDC_PULS_OXIM_PULS_RATE"> <state not-available="true"/> </Nu-Observed-Value> </Numeric> </Channel> </VMD> </Simple_MDS> --> <id value="example"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p>Example of a simple MDS from a pulse oximeter containment tree</p> </div> </text> <contained> <Device> <id value="d1"/> <identifier> <type> <coding> <system value="http://hl7.org/fhir/identifier-type"/> <code value="SNO"/> </coding> </type> <value value="ID 13.1"/> </identifier> <identifier> <type> <text value="Global Medical Device Nomenclature"/> </type> <system value="urn:iso:std:iso:11073:10101"/> <value value="2000"/> </identifier> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="2000"/> <display value="MDC_DEV_ANALY_SAT_O2_MDS"/> </coding> </type> <manufacturer value="Center4MI"/> <model value="2-0-14"/> </Device> </contained> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="2000"/> <display value="MDC_DEV_ANALY_SAT_O2_MDS"/> </coding> </type> <identifier> <type><text value="Handle ID"/></type> <value value="0"/> </identifier> <lastSystemChange value="2014-10-07T14:45:00Z"/> <source> <reference value="#d1"/> </source> <operationalStatus> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="0"/> <display value="disconnected"/> </coding> </operationalStatus> <languageCode> <coding> <system value="http://tools.ietf.org/html/bcp47"/> <code value="en-US"/> </coding> </languageCode> </DeviceComponent>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.