Connectathon 11 Snapshot

This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Detectedissue-example-dup.xml

Raw XML (canonical form)

Diagnostic order is placed when a recent image of the same body site already exists (id = "duplicate")

<DetectedIssue xmlns="http://hl7.org/fhir">
  <id value="duplicate"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
      <p>Similar test was performed within the past 14 days</p>
      <ul>
        <li>
          <a href="DiagnosticOrder/id">Chest CT - ordered May 8, 2013 by Dr. Adam Careful</a>
        </li>
        <li>
          <a href="ImagingStudy/example">Image 1 from Series 3: CT Images on Patient MINT (MINT1234) taken at 1-Jan 2011 01:20
             AM</a>
        </li>
      </ul>
    </div>
  </text>
  <!--   test 1   -->
  <category>
    <coding>
      <system value="http://hl7.org/fhir/v3/ActCode"/>
      <code value="DUPTHPY"/>
      <display value="Duplicate Therapy Alert"/>
    </coding>
  </category>
  <implicated>
    <reference value="DiagnosticOrder/di"/>
    <display value="Chest CT - ordered May 8, 2013 by Dr. Adam Careful"/>
  </implicated>
  <!--   test 2   -->
  <implicated>
    <reference value="ImagingStudy/example"/>
    <display value="Image 1 from Series 3: CT Images on Patient MINT (MINT1234) taken at 1-Jan 2011 01:20
     AM"/>
  </implicated>
  <detail value="Similar test was performed within the past 14 days"/>
  <date value="2013-05-08"/>
  <author>
    <reference value="Device/dsp"/>
  </author>
</DetectedIssue>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.