This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Export of DocumentManifest to Media (id = "example-media")
<AuditEvent xmlns="http://hl7.org/fhir"> <id value="example-media"/> <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-media</p><h3>Events</h3><table><tr><td>-</td><td><b>Type</b></td><td><b>Subtype</b></td><td><b>Action</b></td><td><b>DateTime</b></td><td><b>Outcome</b></td></tr><tr><td>*</td><td>Export (Details: http://nema.org/dicom/dicm code 110106 = 'Export', stated as 'Export')</td><td>Distribute Document Set on Media (Details: urn:oid:1.3.6.1.4.1.19376.1.2 code ITI-32 = '??', stated as 'Distribute Document Set on Media')</td><td>R</td><td>28/08/2015 9:42:24 AM</td><td>0</td></tr></table><blockquote><p><b>participant</b></p><p><b>role</b>: Source Role ID <span>(Details : {http://nema.org/dicom/dicm code '110153' = 'Source Role ID', given as 'Source Role ID'})</span></p><p><b>userId</b>: ExportToMedia.app</p><p><b>requestor</b>: false</p></blockquote><blockquote><p><b>participant</b></p><p><b>userId</b>: 95</p><p><b>altId</b>: 601847123</p><p><b>name</b>: Grahame Grieve</p><p><b>requestor</b>: true</p></blockquote><blockquote><p><b>participant</b></p><p><b>name</b>: Media title: Hello World</p><p><b>requestor</b>: false</p><p><b>media</b>: DVD (Details: http://nema.org/dicom/dicm code 110033 = 'DVD', stated as 'DVD')</p></blockquote><h3>Sources</h3><table><tr><td>-</td><td><b>Identifier</b></td></tr><tr><td>*</td><td>hl7connect.healthintersections.com.au</td></tr></table><blockquote><p><b>object</b></p><p><b>identifier</b>: e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO</p><p><b>type</b>: Person (Details: http://hl7.org/fhir/object-type code 1 = 'Person', stated as 'Person')</p><p><b>role</b>: Patient (Details: http://hl7.org/fhir/object-role code 1 = 'Patient', stated as 'Patient')</p></blockquote><blockquote><p><b>object</b></p><p><b>identifier</b>: submission set classificationNode = e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO</p><p><b>type</b>: System Object (Details: http://hl7.org/fhir/object-type code 2 = 'System Object', stated as 'System Object')</p><p><b>role</b>: Job (Details: http://hl7.org/fhir/object-role code 20 = 'Job', stated as 'Job')</p></blockquote><blockquote><p><b>object</b></p><p><b>reference</b>: <a>DocumentManifest/example</a></p><p><b>type</b>: System Object (Details: http://hl7.org/fhir/object-type code 2 = 'System Object', stated as 'System Object')</p></blockquote></div></text><event> <type> <system value="http://nema.org/dicom/dicm"/> <code value="110106"/> <display value="Export"/> </type> <subtype> <system value="urn:oid:1.3.6.1.4.1.19376.1.2"/> <code value="ITI-32"/> <display value="Distribute Document Set on Media"/> </subtype> <action value="R"/> <dateTime value="2015-08-27T23:42:24Z"/> <outcome value="0"/> </event> <participant> <!-- Source active participant, the software making the PIX query UserId - The identity of the Patient Identifier Cross-reference Consumer Actor facility and sending application from the HL7 message; concatenated together, separated by the | character. AlternativeUserId - Process ID --> <role> <coding> <system value="http://nema.org/dicom/dicm"/> <code value="110153"/> <display value="Source Role ID"/> </coding> </role> <userId> <value value="ExportToMedia.app"/> </userId> <requestor value="false"/> </participant> <participant> <!-- The Human using the software, if known --> <userId> <value value="95"/> </userId> <altId value="601847123"/> <name value="Grahame Grieve"/> <requestor value="true"/> </participant> <participant> <!-- The media exported onto --> <name value="Media title: Hello World"/> <requestor value="false"/> <media> <system value="http://nema.org/dicom/dicm"/> <code value="110033"/> <display value="DVD"/> </media> </participant> <source> <identifier> <value value="hl7connect.healthintersections.com.au"/> </identifier> </source> <object> <!-- The Patient --> <identifier> <value value="e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO"/> </identifier> <type> <system value="http://hl7.org/fhir/object-type"/> <code value="1"/> <display value="Person"/> </type> <role> <system value="http://hl7.org/fhir/object-role"/> <code value="1"/> <display value="Patient"/> </role> </object> <object> <!-- The SubmissionSet identifier --> <identifier> <type> <coding> <system value="urn:uuid:a54d6aa5-d40d-43f9-88c5-b4633d873bdd"/> <code value="IHE XDS Metadata"/> <display value="submission set classificationNode"/> </coding> </type> <value value="e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO"/> </identifier> <type> <system value="http://hl7.org/fhir/object-type"/> <code value="2"/> <display value="System Object"/> </type> <role> <system value="http://hl7.org/fhir/object-role"/> <code value="20"/> <display value="Job"/> </role> </object> <object> <!-- The Document Manifest exported --> <reference> <reference value="DocumentManifest/example"/> </reference> <type> <system value="http://hl7.org/fhir/object-type"/> <code value="2"/> <display value="System Object"/> </type> </object> </AuditEvent>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.