This page is part of the FHIR Specification (v1.0.0: DSTU 2 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
USLabOrder Blood Lead (id = "do-uslab-example1")
<DiagnosticOrder xmlns="http://hl7.org/fhir"> <id value="do-uslab-example1"/> <!-- comment out to see if causing build to hang extension for a CC to a non ordering party in this case another provider <extension url="http://hl7.org/fhir/StructureDefinition/uslab-cc-practitioner"> <valueReference> <reference value="Practitioner/uslab-example2"/> <display value="Dr Bill T Lookafter Jr"/> </valueReference> </extension> --> <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: do-uslab-example1</p><p><b>subject</b>: <a>Todd Lerr</a></p><p><b>orderer</b>: <a>Dr Leonard T Bloodraw Jr</a></p><p><b>identifier</b>: ORD000123A (OFFICIAL)</p><p><b>reason</b>: Abnormal lead level in blood <span>(Details : {http://www.icd10data.com/icd10pcs code 'R78.71' = '??', given as 'Abnormal lead level in blood'})</span></p><p><b>supportingInformation</b>: <a>Prior Results Observation</a>, <a>Lead Exposure</a></p><p><b>status</b>: requested</p><p><b>priority</b>: routine</p><h3>Events</h3><table><tr><td>-</td><td><b>Status</b></td><td><b>Description</b></td><td><b>DateTime</b></td></tr><tr><td>*</td><td>requested</td><td>new-request <span>(Details : {[not stated] code 'new-request' = '??)</span></td><td>04/12/2014 3:42:15 PM</td></tr></table><h3>Items</h3><table><tr><td>-</td><td><b>Code</b></td><td><b>Specimen</b></td><td><b>Status</b></td></tr><tr><td>*</td><td>Blood Lead <span>(Details : {LOINC code '5671-3' = 'Lead [Mass/volume] in Blood', given as 'Lead [Mass/volume] in Blood'}; {urn:oid:2.16.840.1.113883.3.72.5.24 code 'BLDLD' = '??', given as 'Blood Lead'})</span></td><td><a>Whole blood</a></td><td>requested</td></tr></table><p><b>note</b>: patient is afraid of needles</p></div></text><subject> <reference value="Patient/patient-uslab-example1"/> <display value="Todd Lerr"/> </subject> <orderer> <reference value="Practitioner/pract-uslab-example1"/> <display value="Dr Leonard T Bloodraw Jr"/> </orderer> <identifier> <use value="official"/> <!-- EH Using an OID here but could any URI eg http://aceclinic.com --> <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/> <value value="ORD000123A"/> </identifier> <reason> <coding> <system value="http://www.icd10data.com/icd10pcs"/> <code value="R78.71"/> <display value="Abnormal lead level in blood"/> </coding> <text value="Abnormal lead level in blood"/> </reason> <supportingInformation> <reference value="Observation/obs-uslab-example1"/> <display value="Prior Results Observation"/> </supportingInformation> <supportingInformation> <reference value="Condition/cond-uslab-example1"/> <display value="Lead Exposure"/> </supportingInformation> <!-- EH this specimen is for when lab has existing <specimen> <reference value="Specimen/uslab-example1"/> <display value="Whole blood"/> </specimen> --> <!-- EH this is set to 'requested' by the Placer --> <status value="requested"/> <priority value="routine"/> <event> <!-- EH this is set to 'requested' by the Placer is required element in core resource --> <status value="requested"/> <!-- EH:bound to closed value setUSLAB Diagnostic Order Event Codes --> <description> <coding> <code value="new-request"/> </coding> </description> <!-- EH: Showing dateTime to ss with TZO although only needed to Day --> <dateTime value="2014-12-04T15:42:15-08:00"/> <!-- EH: the event is the order placer requesting a test --> </event> <item> <!-- EH : The local and /or LOINC test codes go here --> <code> <!-- EH: LOINC code gos here --> <coding> <system value="http://loinc.org"/> <code value="5671-3"/> <display value="Lead [Mass/volume] in Blood"/> <!-- EH: LOINC code gos here --> </coding> <coding> <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/> <code value="BLDLD"/> <display value="Blood Lead"/> </coding> <text value="Blood Lead"/> </code> <specimen> <reference value="Specimen/spec-uslab-example1"/> <display value="Whole blood"/> </specimen> <!-- EH this is set to 'requested' by the Placer --> <status value="requested"/> </item> <note> <text value="patient is afraid of needles"/> </note> </DiagnosticOrder>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.