This page is part of the FHIR Specification (v1.0.0: DSTU 2 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
USLabOrder Blood Lead
{ "resourceType": "DiagnosticOrder", "id": "do-uslab-example1", "text": { "fhir_comments": [ " comment out to see if causing build to hang extension for a CC to a non ordering party in this case another provider\n\t<extension url=\"http://hl7.org/fhir/StructureDefinition/uslab-cc-practitioner\">\n\t\t<valueReference>\n\t\t\t<reference value=\"Practitioner/uslab-example2\"/>\n\t\t\t<display value=\"Dr Bill T Lookafter Jr\"/>\n\t\t</valueReference>\n\t</extension>\n " ], "status": "generated", "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: do-uslab-example1</p><p><b>subject</b>: <a>Todd Lerr</a></p><p><b>orderer</b>: <a>Dr Leonard T Bloodraw Jr</a></p><p><b>identifier</b>: ORD000123A (OFFICIAL)</p><p><b>reason</b>: Abnormal lead level in blood <span>(Details : {http://www.icd10data.com/icd10pcs code 'R78.71' = '??', given as 'Abnormal lead level in blood'})</span></p><p><b>supportingInformation</b>: <a>Prior Results Observation</a>, <a>Lead Exposure</a></p><p><b>status</b>: requested</p><p><b>priority</b>: routine</p><h3>Events</h3><table><tr><td>-</td><td><b>Status</b></td><td><b>Description</b></td><td><b>DateTime</b></td></tr><tr><td>*</td><td>requested</td><td>new-request <span>(Details : {[not stated] code 'new-request' = '??)</span></td><td>04/12/2014 3:42:15 PM</td></tr></table><h3>Items</h3><table><tr><td>-</td><td><b>Code</b></td><td><b>Specimen</b></td><td><b>Status</b></td></tr><tr><td>*</td><td>Blood Lead <span>(Details : {LOINC code '5671-3' = 'Lead [Mass/volume] in Blood', given as 'Lead [Mass/volume] in Blood'}; {urn:oid:2.16.840.1.113883.3.72.5.24 code 'BLDLD' = '??', given as 'Blood Lead'})</span></td><td><a>Whole blood</a></td><td>requested</td></tr></table><p><b>note</b>: patient is afraid of needles</p></div>" }, "subject": { "reference": "Patient/patient-uslab-example1", "display": "Todd Lerr" }, "orderer": { "reference": "Practitioner/pract-uslab-example1", "display": "Dr Leonard T Bloodraw Jr" }, "identifier": [ { "use": "official", "system": "urn:oid:2.16.840.1.113883.3.72.5.24", "_system": { "fhir_comments": [ " EH Using an OID here but could any URI eg http://aceclinic.com " ] }, "value": "ORD000123A" } ], "reason": [ { "coding": [ { "system": "http://www.icd10data.com/icd10pcs", "code": "R78.71", "display": "Abnormal lead level in blood" } ], "text": "Abnormal lead level in blood" } ], "supportingInformation": [ { "reference": "Observation/obs-uslab-example1", "display": "Prior Results Observation" }, { "reference": "Condition/cond-uslab-example1", "display": "Lead Exposure" } ], "status": "requested", "_status": { "fhir_comments": [ " EH this specimen is for when lab has existing\n<specimen>\n\t\t<reference value=\"Specimen/uslab-example1\"/>\n\t\t<display value=\"Whole blood\"/>\n\t</specimen>\n ", " EH this is set to 'requested' by the Placer " ] }, "priority": "routine", "event": [ { "fhir_comments": [ " EH: the event is the order placer requesting a test " ], "status": "requested", "_status": { "fhir_comments": [ " EH this is set to 'requested' by the Placer is required element in core resource " ] }, "description": { "fhir_comments": [ " EH:bound to closed value setUSLAB Diagnostic Order Event Codes " ], "coding": [ { "code": "new-request" } ] }, "dateTime": "2014-12-04T15:42:15-08:00", "_dateTime": { "fhir_comments": [ " EH: Showing dateTime to ss with TZO although only needed to Day " ] } } ], "item": [ { "code": { "fhir_comments": [ " EH : The local and /or LOINC test codes go here " ], "coding": [ { "fhir_comments": [ " EH: LOINC code gos here ", " EH: LOINC code gos here " ], "system": "http://loinc.org", "code": "5671-3", "display": "Lead [Mass/volume] in Blood" }, { "system": "urn:oid:2.16.840.1.113883.3.72.5.24", "code": "BLDLD", "display": "Blood Lead" } ], "text": "Blood Lead" }, "specimen": [ { "reference": "Specimen/spec-uslab-example1", "display": "Whole blood" } ], "status": "requested", "_status": { "fhir_comments": [ " EH this is set to 'requested' by the Placer " ] } } ], "note": [ { "text": "patient is afraid of needles" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.