DSTU2 QA Preview

This page is part of the FHIR Specification (v1.0.0: DSTU 2 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Daf\valueset-daf-observation-ccdasmokingstatus.json

Raw JSON (canonical form)

Definition for Value SetSmoking Status

{
  "resourceType": "ValueSet",
  "id": "daf-observation-ccdasmokingstatus",
  "meta": {
    "lastUpdated": "2015-09-01T14:38:48.206+10:00",
    "profile": [
      "http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"
    ]
  },
  "text": {
    "status": "generated",
    "div": "<div>!-- Snipped for Brevity --></div>"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/valueset-oid",
      "valueUri": "urn:oid:2.16.840.1.113883.4.642.2.0"
    }
  ],
  "url": "http://hl7.org/fhir/ValueSet/daf-observation-ccdasmokingstatus",
  "version": "1.0.0",
  "name": "Smoking Status",
  "status": "active",
  "experimental": true,
  "publisher": "FHIR OO CDA Template team",
  "contact": [
    {
      "telecom": [
        {
          "system": "other",
          "value": "http://hl7.org/fhir"
        }
      ]
    }
  ],
  "date": "2015-09-01T14:38:48+10:00",
  "description": "This value set indicates the current smoking status of a patient. The vocabulary selected for this value set is the best approximation of the statuses in Meaningful Use (MU) Stage 1. The smoking status value set includes a special code to communicate if the smoking status is unknown",
  "_description": {
    "fhir_comments": [
      "  Value Set: Smoking Status 2.16.840.1.113883.11.20.9.38 STATIC 2012-07-01\nCode System(s)  SNOMED CT 2.16.840.1.113883.6.96  Note the base resource does not allow for display terms -Gforge ticket Item and expansion doesn;t allow for time less than a seconde for instantiation so assume is to be machine generated.  "
    ]
  },
  "copyright": "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement",
  "compose": {
    "include": [
      {
        "system": "http://snomed.info/sct",
        "version": "http://snomed.info/sct/US1000124/version/20140901",
        "concept": [
          {
            "code": "449868002"
          },
          {
            "code": "428041000124106"
          },
          {
            "code": "8517006"
          },
          {
            "code": "266919005"
          },
          {
            "code": "77176002"
          },
          {
            "code": "266927001"
          },
          {
            "code": "428071000124103"
          },
          {
            "code": "428061000124105"
          }
        ]
      },
      {
        "system": "http://hl7.org/fhir/data-absent-reason",
        "concept": [
          {
            "code": "unknown"
          },
          {
            "code": "not-asked"
          }
        ]
      }
    ]
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.