DSTU2 Ballot Source

This page is part of the FHIR Specification (v0.5.0: DSTU 2 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Valueset-specimen-collection-method.xml

Raw XML (canonical form)

Definition for Value SetSpecimenCollectionMethod

Raw XML

<ValueSet xmlns="http://hl7.org/fhir">
  <id value="valueset-specimen-collection-method"/>
  <meta>
    <lastUpdated value="2015-04-03T14:24:32.000+11:00"/>
    <profile value="http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><!-- Snipped for brevity --></div>
  </text>
  <extension url="http://hl7.org/fhir/StructureDefinition/valueset-oid">
    <valueUri value="urn:oid:2.16.840.1.113883.4.642.2.256"/>
  </extension>
  <url value="http://hl7.org/fhir/vs/specimen-collection-method"/>
  <version value="0.5.0"/>
  <name value="SpecimenCollectionMethod"/>
  <publisher value="FHIR Project team"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://hl7.org/fhir"/>
    </telecom>
  </contact>
  <description value=" This example value set defines a set of codes that can be used to indicate the method
   of collection of a specimen.      It includes values from HL7 v2 table 0048"/>
  <copyright value="This value set includes content from SNOMED CT, which is copyright © 2002+ International
   Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement
   between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement"/>
  <status value="draft"/>
  <experimental value="true"/>
  <compose>
    <include>
      <system value="http://snomed.info/sct"/>
      <concept>
        <code value="119295008"/>
        <display value="Specimen obtained by aspiration"/>
      </concept>
      <concept>
        <code value="413651001"/>
        <display value="Bioptics"/>
      </concept>
      <concept>
        <code value="360020006"/>
        <display value="Extirpation - action"/>
      </concept>
      <concept>
        <code value="430823004"/>
        <display value="Examination of midstream urine specimen"/>
      </concept>
      <concept>
        <code value="16404004"/>
        <display value="Induced"/>
      </concept>
      <concept>
        <code value="67889009"/>
        <display value="Irrigation"/>
      </concept>
      <concept>
        <code value="29240004"/>
        <display value="Autopsy examination"/>
      </concept>
      <concept>
        <code value="45710003"/>
        <display value="Sputum"/>
      </concept>
      <concept>
        <code value="7800008"/>
        <display value="Punctate"/>
      </concept>
      <concept>
        <code value="258431006"/>
        <display value="Scrapings"/>
      </concept>
      <concept>
        <code value="20255002"/>
        <display value="Blushing"/>
      </concept>
      <concept>
        <code value="386147002"/>
        <display value="Smear procedure"/>
      </concept>
      <concept>
        <code value="278450005"/>
        <display value="Finger stick"/>
      </concept>
    </include>
    <include>
      <system value="http://hl7.org/fhir/v2/0488"/>
    </include>
  </compose>
</ValueSet>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.