DSTU2 Ballot Source

This page is part of the FHIR Specification (v0.5.0: DSTU 2 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Valueset-obs-uslab-codedresults.xml

Raw XML (canonical form)

Definition for Value SetUS Laboratory Observation Profile Coded Result Codes

Raw XML

<ValueSet xmlns="http://hl7.org/fhir">
  <id value="valueset-obs-uslab-codedresults"/>
  <meta>
    <lastUpdated value="2015-04-03T14:24:32.000+11:00"/>
    <profile value="http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><!-- Snipped for brevity --></div>
  </text>
  <extension url="http://hl7.org/fhir/StructureDefinition/valueset-oid">
    <valueUri value="urn:oid:2.16.840.1.113883.4.642.2.1568"/>
  </extension>
  <url value="http://hl7.org/fhir/vs/obs-uslab-codedresults"/>
  <version value="0.5.0"/>
  <name value="US Laboratory Observation Profile Coded Result Codes"/><!--  USLabObsCodedResult  SNOMED CT for coded results which includes Organism names, Findings,
   and Qualifier values.  value set  required  Y  valueset-obs-uslab-codedresults
  -->
  <publisher value="HL7 International - Orders and Observations WG"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://hl7.org/fhir"/>
    </telecom>
  </contact>
  <description value="SNOMED CT for coded results This value set includes all concepts from SNOMED CT"/>
  <copyright value="This value set includes content from SNOMED CT, which is copyright © 2002+ International
   Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement
   between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement"/>
  <status value="draft"/>
  <experimental value="true"/>
  <compose>
    <include>
      <system value="http://snomed.info/sct"/>
    </include>
  </compose>
</ValueSet>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.