This page is part of the FHIR Specification (v0.5.0: DSTU 2 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
FHIR Value set/code system definition for HL7 v2 table 0168 ( Processing Priority)
{ "resourceType": "ValueSet", "id": "v2-0168", "meta": { "profile": [ "http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition" ] }, "text": { "status": "additional", "div": "<div>!-- Snipped for Brevity --></div>" }, "url": "http://hl7.org/fhir/v2/vs/0168", "version": "2.7", "name": "v2 Processing Priority", "publisher": "HL7, Inc", "contact": [ { "telecom": [ { "system": "url", "value": "http://hl7.org" } ] } ], "description": "FHIR Value set/code system definition for HL7 v2 table 0168 ( Processing Priority)", "status": "active", "experimental": true, "date": "2011-01-28", "define": { "system": "http://hl7.org/fhir/v2/0168", "caseSensitive": true, "concept": [ { "code": "A", "display": "As soon as possible (a priority lower than stat)" }, { "code": "B", "display": "Do at bedside or portable (may be used with other codes)" }, { "code": "C", "display": "Measure continuously (e.g., arterial line blood pressure)" }, { "code": "P", "display": "Preoperative (to be done prior to surgery)" }, { "code": "R", "display": "Routine" }, { "code": "S", "display": "Stat (do immediately)" }, { "code": "T", "display": "Timing critical (do as near as possible to requested time)" } ] } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.