Blood Pressure Measurement
{
"resourceType": "Bundle",
"id": "blood-pressure",
"meta": {
"lastUpdated": "2014-01-30T22:35:23+11:00"
},
"type": "collection",
"base": "http://hl7.org/fhir",
"entry": [
{
"resource": {
"resourceType": "Observation",
"id": "34252345234",
"meta": {
"lastUpdated": "2014-01-30T22:35:23+11:00"
},
"text": {
"status": "generated",
"div": "<div>!-- Snipped for Brevity --></div>"
},
"code": {
"coding": [
{
"system": "http://loinc.org",
"code": "55284-4",
"display": "Blood pressure systolic & diastolic"
}
]
},
"interpretation": {
"coding": [
{
"system": "http://hl7.org/fhir/v2/0078",
"code": "L",
"display": "Below low normal"
}
],
"text": "low"
},
"appliesDateTime": "2012-09-17",
"status": "final",
"reliability": "ok",
"identifier": [
{
"system": "urn:ietf:rfc:3986",
"value": "urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281"
}
],
"subject": {
"reference": "Patient/example"
},
"performer": [
{
"reference": "Practitioner/example"
}
],
"related": [
{
"type": "has-component",
"target": {
"reference": "http://acme.org/ehr/observations/34252345234-s"
}
},
{
"type": "has-component",
"target": {
"reference": "http://acme.org/ehr/observations/34252345234-d"
}
}
]
}
},
{
"resource": {
"resourceType": "Observation",
"id": "34252345234-s",
"meta": {
"lastUpdated": "2014-01-30T22:35:23+11:00"
},
"text": {
"status": "generated",
"div": "<div>!-- Snipped for Brevity --></div>"
},
"code": {
"coding": [
{
"system": "http://loinc.org",
"code": "8480-6",
"display": "Systolic blood pressure"
},
{
"system": "http://snomed.info/sct",
"code": "271649006",
"display": "Systolic blood pressure"
},
{
"system": "http://acme.org/devices/clinical-codes",
"code": "bp-s",
"display": "Systolic Blood pressure"
}
]
},
"valueQuantity": {
"value": 107,
"units": "mm[Hg]"
},
"status": "final",
"reliability": "ok",
"subject": {
"reference": "Patient/example"
}
}
},
{
"resource": {
"resourceType": "Observation",
"id": "34252345234-d",
"meta": {
"lastUpdated": "2014-01-30T22:35:23+11:00"
},
"text": {
"status": "generated",
"div": "<div>!-- Snipped for Brevity --></div>"
},
"code": {
"coding": [
{
"system": "http://loinc.org",
"code": "8462-4",
"display": "Diastolic blood pressure"
}
]
},
"valueQuantity": {
"value": 60,
"units": "mm[Hg]"
},
"status": "final",
"reliability": "ok",
"subject": {
"reference": "Patient/example"
}
}
}
]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.