DSTU2 Ballot Source

This page is part of the FHIR Specification (v0.5.0: DSTU 2 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Obs-uslab-example4.xml

Raw XML (canonical form)

USLab Ratio Observation Profile Example: Dengue Titer (id = "uslab-example4")

Raw XML

<Observation xmlns="http://hl7.org/fhir">
  <id value="uslab-example4"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><!-- Snipped for brevity --></div>
  </text><!--    FHIR build is generating the narratives
&lt;text&gt;
    &lt;status value=&quot;generated&quot;/&gt;
    &lt;div xmlns=&quot;http://www.w3.org/1999/xhtml&quot;&gt;
      &lt;ul&gt;
        &lt;li&gt; obs-uslab-example4.xml&lt;/li&gt;
        &lt;li&gt; id: uslab-example4&lt;/li&gt;
        &lt;li&gt; Name: USLab Observation Example4&lt;/li&gt;
        &lt;li&gt;Description: USLab Ratio Observation Profile Canonical Example: Dengue Virus&lt;/li&gt
  ;
      &lt;/ul&gt;
    &lt;/div&gt;
  &lt;/text&gt;
   --><!--    extension for specimen reject goes here - not for this use case
  &lt;extension url=&quot;http://hl7.org/fhir/StructureDefinition/uslabspecimenrejectreason&quot;&gt;
    &lt;valueCodeableConcept&gt;
      &lt;coding&gt;
        &lt;system value=&quot;http://hl7.org/fhir/v2/0490&quot;/&gt;
        &lt;code value=&quot;EX&quot;/&gt;
        &lt;display value=&quot;Expired&quot;/&gt;
      &lt;/coding&gt;
    &lt;/valueCodeableConcept&gt;
  &lt;/extension&gt;
   --><!--    extension for observation kindt goes here    -->
  <extension url="http://hl7.org/fhir/StructureDefinition/uslabobservationkind">
    <valueCode value="result"/>
  </extension><!--   EH :  The local and /or LOINC test codes go here    -->
  <code><!--    EH: LOINC code goes here   -->
    <coding>
      <system value="http://loinc.org"/>
      <code value="6812-2"/>
      <display value="Dengue virus IgM Ab [Titer] in Serum"/>
    </coding><!--    EH: LOINC code goes here   -->
    <coding>
      <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/>
      <code value="DGIGM"/>
      <display value="Dengue IgM QN"/>
    </coding>
    <text value="Dengue IgM Titer"/>
  </code><!--    In FHIR, units may be represented twice. Once in the
    agreed human representation, and once in a coded form.
    Both is best, since it's not always possible to infer
    one from the other in code.

    When a computable unit is provided, UCUM (http://unitsofmeasure.org)
    is always preferred, but it doesn't provide notional units (such as
    &quot;tablet&quot;), etc. For these, something else is required (e.g. Snomed-CT)
      -->
  <valueRatio>
    <numerator>
      <value value="1"/>
    </numerator>
    <denominator>
      <value value="256"/>
    </denominator>
  </valueRatio><!--     eH dataabsent reason  would go here if valueQuantity was empty e.g.:
  &lt;dataAbsentReason value=&quot;error&quot;/&gt;    -->
  <interpretation>
    <coding>
      <system value="http://hl7.org/fhir/v2/0078"/>
      <code value="H"/>
    </coding>
  </interpretation>
  <appliesDateTime value="2014-12-05"/><!--    EH: Showing dateTime to ss with TZO although only needed to Day    -->
  <issued value="2014-12-06T15:42:15-08:00"/>
  <status value="final"/>
  <identifier>
    <use value="official"/>
    <type>
      <text value="lab test result ID"/>
    </type>
    <system value="http://lis.acmelabs.org/identifiers/labtestresult"/>
    <value value="4567"/>
  </identifier>
  <subject>
    <reference value="Patient/uslab-example1"/>
    <display value="Todd Lerr"/>
  </subject>
  <specimen>
    <reference value="Specimen/uslab-example1"/>
    <display value="Bloo sample"/>
  </specimen>
  <performer>
    <reference value="Practitioner/uslab-example1"/>
    <display value="Dr Leonard T Bloodraw Jr"/>
  </performer>
  <referenceRange>
    <text value="&lt;1:64"/>
  </referenceRange>
</Observation>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.