DSTU2 Ballot Source

This page is part of the FHIR Specification (v0.5.0: DSTU 2 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4B R4 R3 R2

Media-example-dicom.xml

Raw XML (canonical form)

Example Ultrasound Image (id = "1.2.840.11361907579238403408700.3.0.14.19970327150033")

Raw XML

<Media xmlns="http://hl7.org/fhir">
  <id value="1.2.840.11361907579238403408700.3.0.14.19970327150033"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><!-- Snipped for brevity --></div>
  </text><!--    
    this is added to demonstrate the use of extensions.
    0002,0010 is the DICOM transfer syntax of the referenced image
      -->
  <extension url="http://nema.org/fhir/extensions#0002-0010">
    <valueUri value="urn:oid:1.2.840.10008.1.2.1"/>
  </extension>
  <type value="photo"/>
  <subtype>
    <coding>
      <system value="http://nema.org/dicom/dicm"/>
      <code value="US"/>
    </coding>
  </subtype>
  <identifier>
    <use value="official"/>
    <type>
      <text value="InstanceUID"/>
    </type>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:1.2.840.11361907579238403408700.3.0.14.19970327150033"/>
  </identifier>
  <identifier>
    <type>
      <text value="accessionNo"/>
    </type><!--    the imaging department accession number. (they recycle numbers each year)    -->
    <system value="http://acme-imaging.com/accession/2012"/>
    <value value="1234567"/>
  </identifier>
  <identifier>
    <type>
      <text value="studyId"/>
    </type>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:1.2.840.113619.2.21.848.34082.0.538976288.3"/>
  </identifier>
  <identifier>
    <type>
      <text value="seriesId"/>
    </type>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:1.2.840.113619.2.21.3408.700.0.757923840.3.0"/>
  </identifier>
  <subject>
    <reference value="Patient/example"/>
  </subject>
  <deviceName value="G.E. Medical Systems"/>
  <height value="480"/>
  <width value="640"/><!--    and a reference to the image data    -->
  <content>
    <contentType value="application/dicom"/><!--    The actual image could be anywhere. This is a WADO example    -->
    <url value="http://imaging.acme.com/wado/server?requestType=WADO&amp;contentType=application%2Fdicom&amp;studyUi
    d=1.2.840.113619.2.21.848.34082.0.538976288.3&amp;seriesUid=1.2.840.113619.2.21.3408.700.0.757923840.
    3.0&amp;objectUid=1.2.840.11361907579238403408700.3.0.14.19970327150033"/>
  </content>
</Media>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.