Rate Goal
<ExtensionDefinition xmlns="http://hl7.org/fhir"> <id value="medicationdispense-rateGoal"/> <url value="http://hl7.org/fhir/ExtensionDefinition/medicationdispense-rateGoal"/> <name value="Rate Goal"/> <display value="rateGoal"/> <publisher value="Health Level Seven, Inc. - FHIR WG"/> <contact> <telecom> <system value="url"/> <value value="HL7"/> </telecom> </contact> <description value="The target rate to reach for this infusion. Note that deliveryRateGoal is typically less than the maximum delivery rate which is the rate not to exceed. For enteral feeding orders, a target tube feeding rate of 75ml/hour may be specified."/> <status value="draft"/> <date value="2015-02-17"/> <contextType value="resource"/> <context value="MedicationDispense.dosageInstruction"/> <element> <path value="Extension"/> <short value="Rate Goal"/> <definition value="The target rate to reach for this infusion. Note that deliveryRateGoal is typically less than the maximum delivery rate which is the rate not to exceed. For enteral feeding orders, a target tube feeding rate of 75ml/hour may be specified."/> <min value="0"/> <max value="1"/> <type> <code value="Ratio"/> </type> </element> </ExtensionDefinition>