2nd DSTU Draft For Comment

This page is part of the FHIR Specification (v0.4.0: DSTU 2 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R3 R2

Devicecomponent-example-prodspec.json

Raw JSON (canonical form)

Example for DeviceComponent includes production specification information

{
  "resourceType": "DeviceComponent",
  "id": "example-prodspec",
  "text": {
    "status": "generated",
    "div": "<div>!-- Snipped for Brevity --></div>"
  },
  "contained": [
    {
      "resourceType": "Device",
      "id": "d1",
      "identifier": [
        {
          "label": "Serial Number",
          "value": "ID 13.1"
        },
        {
          "label": "Global Medical Device Nomenclature",
          "system": "urn:std:iso:11073:10101",
          "value": "2000"
        }
      ],
      "type": {
        "coding": [
          {
            "system": "urn:std:iso:11073:10101",
            "code": "2000",
            "display": "MDC_DEV_ANALY_SAT_O2_MDS"
          }
        ]
      },
      "manufacturer": "Center4MI",
      "model": "2-0-14"
    }
  ],
  "type": {
    "coding": [
      {
        "system": "urn:std:iso:11073:10101",
        "code": "2000",
        "display": "MDC_DEV_ANALY_SAT_O2_MDS"
      }
    ]
  },
  "identifier": {
    "label": "Handle ID",
    "value": "0"
  },
  "lastSystemChange": "2014-10-07T14:45:00Z",
  "source": {
    "reference": "#d1"
  },
  "operationalStatus": [
    {
      "coding": [
        {
          "system": "urn:std:iso:11073:10101",
          "code": "0",
          "display": "disconnected"
        }
      ]
    }
  ],
  "productionSpecification": [
    {
      "specType": {
        "coding": [
          {
            "code": "1",
            "display": "Serial number"
          }
        ]
      },
      "productionSpec": "xa-12324-b"
    },
    {
      "specType": {
        "coding": [
          {
            "code": "3",
            "display": "Hardware version"
          }
        ]
      },
      "productionSpec": "1.1"
    },
    {
      "specType": {
        "coding": [
          {
            "code": "4",
            "display": "Software version"
          }
        ]
      },
      "productionSpec": "1.12"
    },
    {
      "specType": {
        "coding": [
          {
            "code": "5",
            "display": "Firmware version"
          }
        ]
      },
      "productionSpec": "1.0.23"
    }
  ],
  "languageCode": {
    "coding": [
      {
        "system": "http://tools.ietf.org/html/bcp47",
        "code": "en-US"
      }
    ]
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.