This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.

Valueset-specimen-status.xml

Raw XML (canonical form)

Definition for Value SetSpecimenStatus

<ValueSet xmlns="http://hl7.org/fhir">
  <id value="specimen-status"/>
  <meta>
    <lastUpdated value="2015-12-03T09:57:31.744+11:00"/>
    <profile value="http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
      <h2>SpecimenStatus</h2>
      <p>Codes providing the status/availability of a specimen.</p>
      <p>This value set has an inline code system http://hl7.org/fhir/specimen-status, which defines
         the following codes:</p>
      <table class="codes">
        <tr>
          <td>
            <b>Code</b>
          </td>
          <td>
            <b>Display</b>
          </td>
          <td>
            <b>Definition</b>
          </td>
        </tr>
        <tr>
          <td>available
            <a name="available"> </a>
          </td>
          <td>Available</td>
          <td>The physical specimen is present and in good condition.</td>
        </tr>
        <tr>
          <td>unavailable
            <a name="unavailable"> </a>
          </td>
          <td>Unavailable</td>
          <td>There is no physical specimen because it is either lost, destroyed or consumed.</td>
        </tr>
        <tr>
          <td>unsatisfactory
            <a name="unsatisfactory"> </a>
          </td>
          <td>Unsatisfactory</td>
          <td>The specimen cannot be used because of a quality issue such as a broken container, contamination,
             or too old.</td>
        </tr>
        <tr>
          <td>entered-in-error
            <a name="entered-in-error"> </a>
          </td>
          <td>Entered-in-error</td>
          <td>The specimen was entered in error and therefore nullified.</td>
        </tr>
      </table>
    </div>
  </text>
  <extension url="http://hl7.org/fhir/StructureDefinition/valueset-oid">
    <valueUri value="urn:oid:2.16.840.1.113883.4.642.2.426"/>
  </extension>
  <url value="http://hl7.org/fhir/ValueSet/specimen-status"/>
  <version value="1.1.0"/>
  <name value="SpecimenStatus"/>
  <status value="draft"/>
  <experimental value="false"/>
  <publisher value="HL7 (FHIR Project)"/>
  <contact>
    <telecom>
      <system value="other"/>
      <value value="http://hl7.org/fhir"/>
    </telecom>
    <telecom>
      <system value="email"/>
      <value value="fhir@lists.hl7.org"/>
    </telecom>
  </contact>
  <date value="2015-12-03T09:57:31+11:00"/>
  <description value="Codes providing the status/availability of a specimen."/>
  <codeSystem>
    <extension url="http://hl7.org/fhir/StructureDefinition/valueset-oid">
      <valueUri value="urn:oid:2.16.840.1.113883.4.642.1.426"/>
    </extension>
    <system value="http://hl7.org/fhir/specimen-status"/>
    <version value="1.1.0"/>
    <caseSensitive value="true"/>
    <concept>
      <code value="available"/>
      <display value="Available"/>
      <definition value="The physical specimen is present and in good condition."/>
    </concept>
    <concept>
      <code value="unavailable"/>
      <display value="Unavailable"/>
      <definition value="There is no physical specimen because it is either lost, destroyed or consumed."/>
    </concept>
    <concept>
      <code value="unsatisfactory"/>
      <display value="Unsatisfactory"/>
      <definition value="The specimen cannot be used because of a quality issue such as a broken container, contamination,
       or too old."/>
    </concept>
    <concept>
      <code value="entered-in-error"/>
      <display value="Entered-in-error"/>
      <definition value="The specimen was entered in error and therefore nullified."/>
    </concept>
  </codeSystem>