GAO Ballot Package

This page is part of the FHIR Specification (v1.1.0: STU 3 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.

Dataelement-sdc-profile-example-de.xml

Raw XML (canonical form)

Patient gender represented according to SDC rules (id = "dataelement-sdc-profile-example-de")

<DataElement xmlns="http://hl7.org/fhir">
  <id value="dataelement-sdc-profile-example-de"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml">TODO</div>
  </text>
  <contained>
    <ValueSet>
      <id value="vm-valueset"/>
      <identifier>
        <system value="http://r.details.loinc.org/AnswerList"/>
        <value value="LL2827-5"/>
      </identifier>
      <name value="AHRQ_M/F/UNK"/>
      <status value="active"/>
      <description value="AHRQ Common Formats answer list for Patient and Neonate Gender"/>
      <compose>
        <include>
          <system value="http://loinc.org"/>
          <concept>
            <extension url="http://hl7.org/fhir/StructureDefinition/valueset-conceptOrder">
              <valueInteger value="1"/>
            </extension>
            <code value="a"/>
            <display value="Male"/>
            <designation>
              <use>
                <display value="Answer ID"/>
              </use>
              <value value="LA2-8"/>
            </designation>
          </concept>
          <concept>
            <extension url="http://hl7.org/fhir/StructureDefinition/valueset-conceptOrder">
              <valueInteger value="2"/>
            </extension>
            <code value="b"/>
            <display value="Female"/>
            <designation>
              <use>
                <display value="Answer ID"/>
              </use>
              <value value="LA3-6"/>
            </designation>
          </concept>
          <concept>
            <extension url="http://hl7.org/fhir/StructureDefinition/valueset-conceptOrder">
              <valueInteger value="3"/>
            </extension>
            <code value="c"/>
            <display value="Unknown"/>
            <designation>
              <use>
                <display value="Answer ID"/>
              </use>
              <value value="LA4489-6"/>
            </designation>
          </concept>
        </include>
      </compose>
    </ValueSet>
  </contained>
  <contained>
    <ValueSet>
      <id value="pv-valueset"/>
    <!--       
         Side notes:
          - "1" is not a valid code system version for AdministrativeGender
          - The definition and display name for code "UN" is not valid
               -->
      <status value="draft"/>
      <compose>
        <include>
          <extension url="http://hl7.org/fhir/StructureDefinition/valueset-systemName">
            <valueString value="HL7 AdministrativeGender"/>
          </extension>
          <system value="http://hl7.org/fhir/v3/AdministrativeGender"/>
          <version value="1"/>
          <concept>
            <code value="M"/>
            <display value="Male"/>
          </concept>
          <concept>
            <code value="F"/>
            <display value="Female"/>
          </concept>
        </include>
        <include>
          <extension url="http://hl7.org/fhir/StructureDefinition/valueset-systemName">
            <valueString value="HL7 NullFlavor"/>
          </extension>
          <system value="http://hl7.org/fhir/v3/NullFlavor"/>
          <concept>
            <code value="UNK"/>
            <display value="Unknown"/>
          </concept>
        </include>
      </compose>
    </ValueSet>
  </contained>
  <contained>
    <ConceptMap>
      <id value="pv-conceptmap"/>
      <status value="draft"/>
      <sourceUri value="#vm-valueset"/>
      <targetUri value="#pv-valueset"/>
      <element>
        <codeSystem value="http://loinc.org"/>
        <code value="a"/>
        <target>
          <codeSystem value="http://hl7.org/fhir/v3/AdministrativeGender"/>
          <code value="M"/>
          <equivalence value="equivalent"/>
        </target>
      </element>
      <element>
        <codeSystem value="http://loinc.org"/>
        <code value="b"/>
        <target>
          <codeSystem value="http://hl7.org/fhir/v3/AdministrativeGender"/>
          <code value="F"/>
          <equivalence value="equivalent"/>
        </target>
      </element>
      <element>
        <codeSystem value="http://loinc.org"/>
        <code value="c"/>
        <target>
          <codeSystem value="http://hl7.org/fhir/v3/Unknown"/>
          <code value="UNK"/>
          <equivalence value="equivalent"/>
        </target>
      </element>
    </ConceptMap>
  </contained>
  <contained>
    <Organization>
      <id value="sub-org"/>
      <name value="Agency for Healthcare Research and Quality (AHRQ) Center for Patient Safety and Quality"/>
      <address>
        <text value="540 Gaither Rd Rockvill MD 20850"/>
      </address>
      <contact>
        <name>
          <text value="Bill Munier"/>
        </name>
        <telecom>
          <system value="email"/>
          <value value="william.munier@ahrq.hhs.gov"/>
        </telecom>
      </contact>
    </Organization>
  </contained>
  <extension url="http://hl7.org/fhir/StructureDefinition/11179-de-document-reference">
    <valueReference>
      <reference value="#doc"/>
    </valueReference>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/11179-de-effective-period">
    <valuePeriod>
      <start value="2010-03-31"/>
    </valuePeriod>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/11179-de-submitter-org">
    <valueReference>
      <reference value="#sub-org"/>
    </valueReference>
  </extension>
  <identifier>
    <system value="http://nlm.nih.gov/some_other_text/data_element_identifier"/>
    <value value="DE42AHRQ"/>
  </identifier>
  <version value="1.2"/>
  <name value="Patient Gender"/>
  <status value="draft"/>
  <publisher value="Agency for Healthcare Research and Quality (AHRQ) Center for Patient Safety and Quality"/>
  <contact>
    <extension url="http://hl7.org/fhir/StructureDefinition/11179-de-contact-address">
      <valueAddress>
        <text value="540 Gaither Rd Rockville MD 20850"/>
      </valueAddress>
    </extension>
    <name value="Bill Munier"/>
    <telecom>
      <system value="email"/>
      <value value="william.munier@ahrq.hhs.gov"/>
    </telecom>
  </contact>
  <date value="2010-03-31"/>
  <useContext>
    <coding>
      <code value="Healthcare Event Reporting Form"/>
    <!--        Wasn't clear if the above was a code        -->
      <display value="Patient safety event report - hospital: healthcare event reporting form"/>
    </coding>
  </useContext>
  <mapping>
    <identity value="objclass"/>
    <uri value="http://healthit.gov/sdc/objectclassproperty"/>
    <name value="Structured Data Capture ObjectClass/Property"/>
  </mapping>
  <element>
    <extension url="http://hl7.org/fhir/StructureDefinition/elementdefinition-question">
      <valueString value="Patient's Gender"/>
    </extension>
    <extension url="http://hl7.org/fhir/StructureDefinition/elementdefinition-question">
      <valueString value="Patient-Gender,CD"/>
    </extension>
    <path value="gender"/>
    <code>
      <extension url="http://hl7.org/fhir/StructureDefinition/11179-de-is-data-element-concept">
        <valueBoolean value="true"/>
      </extension>
      <system value="http://loinc.org"/>
      <code value="74698-2"/>
    </code>
    <definition value="The patient's documented gender on arrival at the hospital."/>
    <type>
      <code value="CodeableConcept"/>
    </type>
    <binding>
      <strength value="required"/>
      <valueSetReference>
        <extension url="http://hl7.org/fhir/StructureDefinition/11179-permitted-value-valueset">
          <valueReference>
            <reference value="#pv-valueset"/>
          </valueReference>
        </extension>
        <extension url="http://hl7.org/fhir/StructureDefinition/11179-permitted-value-valueset">
          <valueReference>
            <reference value="#pv-conceptmap"/>
          </valueReference>
        </extension>
        <reference value="#vm-valueset"/>
      </valueSetReference>
    </binding>
    <mapping>
      <extension url="http://hl7.org/fhir/StructureDefinition/11179-objectClass">
        <valueCoding>
          <system value="http://snomed.info/sct"/>
          <code value="116154003"/>
          <display value="Patient"/>
        </valueCoding>
      </extension>
      <extension url="http://hl7.org/fhir/StructureDefinition/11179-objectClassProperty">
        <valueCoding>
          <system value="http://snomed.info/sct"/>
          <code value="263495000"/>
          <display value="Gender"/>
        </valueCoding>
      </extension>
      <identity value="objclass"/>
      <map value="http://snomed.info/sct#116154003 | http://snomed.info/sct | 263495000"/>
    </mapping>
  </element>
</DataElement>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.