GAO Ballot Package

This page is part of the FHIR Specification (v1.1.0: STU 3 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.

Patient-example-f201-roel.json

Raw JSON (canonical form)

Real-world patient example (anonymized)

{
  "resourceType": "Patient",
  "id": "f201",
  "text": {
    "status": "generated",
    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f201</p><p><b>identifier</b>: BSN = 123456789 (OFFICIAL), BSN = 123456789 (OFFICIAL)</p><p><b>active</b>: true</p><p><b>name</b>: Roel(OFFICIAL)</p><p><b>telecom</b>: ph: +31612345678(MOBILE), ph: +31201234567(HOME)</p><p><b>gender</b>: male</p><p><b>birthDate</b>: 13/03/1960</p><p><b>deceased</b>: false</p><p><b>address</b>: Bos en Lommerplein 280 Amsterdam 1055RW NLD (HOME)</p><p><b>maritalStatus</b>: Legally married <span>(Details : {SNOMED CT code '36629006' = '36629006', given as 'Legally married'}; {http://hl7.org/fhir/v3/MaritalStatus code 'M' = 'Married)</span></p><p><b>multipleBirth</b>: false</p><p><b>photo</b>: </p><h3>Contacts</h3><table><tr><td>-</td><td><b>Relationship</b></td><td><b>Name</b></td><td><b>Telecom</b></td></tr><tr><td>*</td><td>Wife <span>(Details : {SNOMED CT code '127850001' = '127850001', given as 'Wife'}; {http://hl7.org/fhir/patient-contact-relationship code 'partner' = 'Partner)</span></td><td>Ariadne Bor-Jansma</td><td>ph: +31201234567(HOME)</td></tr></table><h3>Communications</h3><table><tr><td>-</td><td><b>Language</b></td><td><b>Preferred</b></td></tr><tr><td>*</td><td>Dutch <span>(Details : {urn:ietf:bcp:47 code 'nl-NL' = '??', given as 'Dutch'})</span></td><td>true</td></tr></table><p><b>managingOrganization</b>: <a>AUMC</a></p></div>"
  },
  "identifier": [
    {
      "use": "official",
      "_use": {
        "fhir_comments": [
          "   The identifier for the person as this patient (fictive)   "
        ]
      },
      "type": {
        "text": "BSN"
      },
      "system": "urn:oid:2.16.840.1.113883.2.4.6.3",
      "value": "123456789"
    },
    {
      "fhir_comments": [
        "   Demographics   "
      ],
      "use": "official",
      "_use": {
        "fhir_comments": [
          "   The identifier for this individual   "
        ]
      },
      "type": {
        "text": "BSN"
      },
      "system": "urn:oid:2.16.840.1.113883.2.4.6.3",
      "value": "123456789"
    }
  ],
  "active": true,
  "_active": {
    "fhir_comments": [
      "   Indicates that the patient is not part of a multiple birth    "
    ]
  },
  "name": [
    {
      "use": "official",
      "_use": {
        "fhir_comments": [
          "   The name associated with the individual (fictive)   "
        ]
      },
      "text": "Roel",
      "family": [
        "Bor"
      ],
      "given": [
        "Roelof Olaf"
      ],
      "prefix": [
        "Drs."
      ],
      "suffix": [
        "PDEng."
      ]
    }
  ],
  "telecom": [
    {
      "system": "phone",
      "_system": {
        "fhir_comments": [
          "   The mobile contact detail for the individual   "
        ]
      },
      "value": "+31612345678",
      "use": "mobile"
    },
    {
      "system": "phone",
      "_system": {
        "fhir_comments": [
          "   The home contact detail for the individual   "
        ]
      },
      "value": "+31201234567",
      "use": "home"
    }
  ],
  "gender": "male",
  "birthDate": "1960-03-13",
  "deceasedBoolean": false,
  "_deceasedBoolean": {
    "fhir_comments": [
      "   The date and time of birth for the individual    "
    ]
  },
  "address": [
    {
      "fhir_comments": [
        "   Indicates that the individual is not deceased   ",
        "   ISO 3166 3 letter code   "
      ],
      "use": "home",
      "_use": {
        "fhir_comments": [
          "   Home address for the individual   "
        ]
      },
      "line": [
        "Bos en Lommerplein 280"
      ],
      "city": "Amsterdam",
      "postalCode": "1055RW",
      "country": "NLD"
    }
  ],
  "maritalStatus": {
    "coding": [
      {
        "fhir_comments": [
          "   Marital status of the person   "
        ],
        "system": "http://snomed.info/sct",
        "code": "36629006",
        "display": "Legally married"
      },
      {
        "system": "http://hl7.org/fhir/v3/MaritalStatus",
        "code": "M"
      }
    ]
  },
  "multipleBirthBoolean": false,
  "photo": [
    {
      "contentType": "image/jpeg",
      "url": "Binary/f006"
    }
  ],
  "contact": [
    {
      "relationship": [
        {
          "fhir_comments": [
            "   Contact of the patient   "
          ],
          "coding": [
            {
              "fhir_comments": [
                "   Indicates that the contact is the patient's wife   "
              ],
              "system": "http://snomed.info/sct",
              "code": "127850001",
              "display": "Wife"
            },
            {
              "system": "http://hl7.org/fhir/patient-contact-relationship",
              "code": "partner"
            }
          ]
        }
      ],
      "name": {
        "use": "usual",
        "_use": {
          "fhir_comments": [
            "   The name of the contact   "
          ]
        },
        "text": "Ariadne Bor-Jansma"
      },
      "telecom": [
        {
          "system": "phone",
          "_system": {
            "fhir_comments": [
              "   The home contact detail   "
            ]
          },
          "value": "+31201234567",
          "use": "home"
        }
      ]
    }
  ],
  "communication": [
    {
      "language": {
        "coding": [
          {
            "system": "urn:ietf:bcp:47",
            "code": "nl-NL",
            "display": "Dutch"
          }
        ]
      },
      "preferred": true
    }
  ],
  "managingOrganization": {
    "reference": "Organization/f201",
    "display": "AUMC"
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.