GAO Ballot Package

This page is part of the FHIR Specification (v1.1.0: STU 3 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.

Diagnosticreport-example-f202-bloodculture.xml

Raw XML (canonical form)

Real-world patient example (id = "f202")

<DiagnosticReport xmlns="http://hl7.org/fhir">
  <id value="f202"/>
  <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f202</p><p><b>contained</b>: </p><p><b>status</b>: final</p><p><b>category</b>: Laboratory test <span>(Details : {SNOMED CT code '15220000' = '15220000', given as 'Laboratory test'}; {http://hl7.org/fhi
          r/v2/0074 code 'LAB' = 'Laboratory)</span></p><p><b>code</b>: Blood culture for bacteria, including anaerobic screen <span>(Details : {SNOMED CT code '104177005' = '104177005', given as 'Blood culture for bacteria,
           including anaerobic screen'})</span></p><p><b>subject</b>: <a>Roel</a></p><p><b>effective</b>: 11/03/2013 3:45:00 AM</p><p><b>issued</b>: 11/03/2013 10:28:00 AM</p><p><b>performer</b>: <a>AUMC</a></p><p><b>request</b>: id: req; Roel</p><p><b>result</b>: <a>Results for staphylococcus analysis on Roel's blood culture</a></p><p><b>conclusion</b>: Blood culture tested positive on staphylococcus aureus</p><p><b>codedDiagnosis</b>: Bacteremia due to staphylococcus <span>(Details : {SNOMED CT code '428763004' = '428763004', given as 'Bacteremia due to staphylococcus'})</span></p></div></text><contained>
    <DiagnosticOrder>
      <id value="req"/>
      <subject>
        <reference value="Patient/f201"/>
        <display value="Roel"/>
      </subject>
      <orderer>
        <reference value="Practitioner/f201"/>
        <display value="Dokter Bronsig"/>
      </orderer>
      <encounter>
        <reference value="Encounter/f203"/>
        <display value="Roel's encounter on March eleventh 2013"/>
      </encounter>
    </DiagnosticOrder>
  </contained>
  <status value="final"/>
  <category>
  <!--    Lab test    -->
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="15220000"/>
      <display value="Laboratory test"/>
    </coding>
    <coding>
      <system value="http://hl7.org/fhir/v2/0074"/>
      <code value="LAB"/>
    </coding>
  </category>
  <code>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="104177005"/>
      <display value="Blood culture for bacteria, including anaerobic screen"/>
    </coding>
  </code>
  <subject>
    <reference value="Patient/f201"/>
    <display value="Roel"/>
  </subject>
  <effectiveDateTime value="2013-03-11T03:45:00+01:00"/>
  <issued value="2013-03-11T10:28:00+01:00"/>
  <performer>
    <reference value="Organization/f201"/>
    <display value="AUMC"/>
  </performer>
<!--    No identifier was available    -->
  <request>
    <reference value="#req"/>
  </request>
  <result>
    <reference value="Observation/f206"/>
    <display value="Results for staphylococcus analysis on Roel's blood culture"/>
  </result>
  <conclusion value="Blood culture tested positive on staphylococcus aureus"/>
  <codedDiagnosis>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="428763004"/>
      <display value="Bacteremia due to staphylococcus"/>
    </coding>
  </codedDiagnosis>
</DiagnosticReport>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.