This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.

Dataelement-labtestmaster-example.xml

Raw XML (canonical form)

Prothrombin time for lab test master file (id = "prothrombin")

<DataElement xmlns="http://hl7.org/fhir">
  <id value="prothrombin"/>
<!--    text>
      generated by build process
    </text     -->
  <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: prothrombin</p><p><b>identifier</b>: Prothrombin Time, PT = 11</p><p><b>name</b>: Prothrombin Time</p><p><b>status</b>: active</p><h3>Mappings</h3><table><tr><td>-</td><td><b>Identity</b></td><td><b>Uri</b></td><td><b>Name</b></td><td><b>Comments</b></td></tr><tr><td>*</td><td>loinc</td><td><a>http://loinc.org/</a></td><td>LOINC</td><td>Version 2.48 or later</td></tr></table><p><b>element</b>: todo-bundle</p></div></text><identifier>
    <type>
      <text value="Prothrombin Time, PT"/>
    </type>
    <system value="http://www.CenturyHospital/Laboratory/DirectoryofServices"/>
    <value value="11"/>
    <period>
      <start value="2011-05-19"/>
    </period>
    <assigner>
      <display value="Century Hospital Laboratory"/>
    </assigner>
  </identifier>
  <name value="Prothrombin Time"/>
  <status value="active"/>
  <mapping>
    <identity value="loinc"/>
    <uri value="http://loinc.org/"/>
    <name value="LOINC"/>
    <comments value="Version 2.48 or later"/>
  </mapping>
  <element>
    <extension url="http://hl7.org/fhir/StructureDefinition/elementdefinition-allowedUnits">
      <valueCodeableConcept>
        <coding>
          <system value="http://unitsofmeasure.org"/>
          <version value="1.9"/>
          <code value="s"/>
          <display value="second"/>
          <userSelected value="true"/>
        </coding>
        <text value="second"/>
      </valueCodeableConcept>
    </extension>
    <path value="prothrombin"/>
    <definition value="The PT test evaluates the extrinsic and common pathways of the coagulation cascade."/>
    <comments value="Used to screen the integrity of the extrinsic and common pathways of coagulation and to
     monitor warfarin anticoagulation. "/>
    <requirements value="This test is orderable. A plasma specimen in a 3.2% sodium citrate blue top tube is required."/>
    <alias value="Protime, PT"/>
    <type>
      <code value="decimal"/>
    </type>
  <!--     Is this the FHIR datatype for the observation? ( ie the datatype when ordering the
     test) or the Result? ( ie. numeric, codeable concept or text for lab tests )    -->
    <exampleDecimal value="10.0"/>
  <!--     Is this the an example result like "10.0"  for the observation/dataelement?     -->
    <mapping>
      <identity value="loinc"/>
      <map value="5964-2"/>
    </mapping>
  </element>
</DataElement>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.