This page is part of the FHIR Specification (v1.1.0: STU 3 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.
Export of DocumentManifest to Media (id = "example-media")
<AuditEvent xmlns="http://hl7.org/fhir"> <id value="example-media"/> <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-media</p><h3>Events</h3><table><tr><td>-</td><td><b>Type</b></td><td><b>Subtype</b></td><td><b>Action</b></td><td><b>DateTime</b></td><td><b>Outcome</b></td></tr><tr><td>*</td><td>Export (Details: http://nema.org/dicom/dicm code 110106 = 'Export', stated as 'Export')</td><td>Distribute Document Set on Media (Details: urn:oid:1.3.6.1.4.1.19376.1.2 code ITI-32 = '??', stated as 'Distribute Document Set on Media')</td><td>R</td><td>28/08/2015 9:42:24 AM</td><td>0</td></tr></table><blockquote><p><b>participant</b></p><p><b>role</b>: Source Role ID <span>(Details : {http://nema.org/dicom/dicm code '110153' = 'Source Role ID', given as 'Source Role ID'})</span></p><p><b>userId</b>: ExportToMedia.app</p><p><b>requestor</b>: false</p></blockquote><blockquote><p><b>participant</b></p><p><b>userId</b>: 95</p><p><b>altId</b>: 601847123</p><p><b>name</b>: Grahame Grieve</p><p><b>requestor</b>: true</p></blockquote><blockquote><p><b>participant</b></p><p><b>name</b>: Media title: Hello World</p><p><b>requestor</b>: false</p><p><b>media</b>: DVD (Details: http://nema.org/dicom/dicm code 110033 = 'DVD', stated as 'DVD')</p></blockquote><h3>Sources</h3><table><tr><td>-</td><td><b>Identifier</b></td></tr><tr><td>*</td><td>hl7connect.healthintersections.com.au</td></tr></table><blockquote><p><b>object</b></p><p><b>identifier</b>: e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO</p><p><b>type</b>: Person (Details: http://hl7.org/fhir/object-type code 1 = 'Person', stated as 'Person')</p><p><b>role</b>: Patient (Details: http://hl7.org/fhir/object-role code 1 = 'Patient', stated as 'Patient')</p></blockquote><blockquote><p><b>object</b></p><p><b>identifier</b>: submission set classificationNode = e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO</p><p><b>type</b>: System Object (Details: http://hl7.org/fhir/object-type code 2 = 'System Object', stated as 'System Object')</p><p><b>role</b>: Job (Details: http://hl7.org/fhir/object-role code 20 = 'Job', stated as 'Job')</p></blockquote><blockquote><p><b>object</b></p><p><b>reference</b>: <a>DocumentManifest/example</a></p><p><b>type</b>: System Object (Details: http://hl7.org/fhir/object-type code 2 = 'System Object', stated as 'System Object')</p></blockquote></div></text><event> <type> <system value="http://nema.org/dicom/dicm"/> <code value="110106"/> <display value="Export"/> </type> <subtype> <system value="urn:oid:1.3.6.1.4.1.19376.1.2"/> <code value="ITI-32"/> <display value="Distribute Document Set on Media"/> </subtype> <action value="R"/> <dateTime value="2015-08-27T23:42:24Z"/> <outcome value="0"/> </event> <participant> <!-- Source active participant, the software making the PIX query UserId - The identity of the Patient Identifier Cross-reference Consumer Actor facility and sending application from the HL7 message; concatenated together, separated by the | character. AlternativeUserId - Process ID --> <role> <coding> <system value="http://nema.org/dicom/dicm"/> <code value="110153"/> <display value="Source Role ID"/> </coding> </role> <userId> <value value="ExportToMedia.app"/> </userId> <requestor value="false"/> </participant> <participant> <!-- The Human using the software, if known --> <userId> <value value="95"/> </userId> <altId value="601847123"/> <name value="Grahame Grieve"/> <requestor value="true"/> </participant> <participant> <!-- The media exported onto --> <name value="Media title: Hello World"/> <requestor value="false"/> <media> <system value="http://nema.org/dicom/dicm"/> <code value="110033"/> <display value="DVD"/> </media> </participant> <source> <identifier> <value value="hl7connect.healthintersections.com.au"/> </identifier> </source> <object> <!-- The Patient --> <identifier> <value value="e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO"/> </identifier> <type> <system value="http://hl7.org/fhir/object-type"/> <code value="1"/> <display value="Person"/> </type> <role> <system value="http://hl7.org/fhir/object-role"/> <code value="1"/> <display value="Patient"/> </role> </object> <object> <!-- The SubmissionSet identifier --> <identifier> <type> <coding> <system value="urn:uuid:a54d6aa5-d40d-43f9-88c5-b4633d873bdd"/> <code value="IHE XDS Metadata"/> <display value="submission set classificationNode"/> </coding> </type> <value value="e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO"/> </identifier> <type> <system value="http://hl7.org/fhir/object-type"/> <code value="2"/> <display value="System Object"/> </type> <role> <system value="http://hl7.org/fhir/object-role"/> <code value="20"/> <display value="Job"/> </role> </object> <object> <!-- The Document Manifest exported --> <reference> <reference value="DocumentManifest/example"/> </reference> <type> <system value="http://hl7.org/fhir/object-type"/> <code value="2"/> <display value="System Object"/> </type> </object> </AuditEvent>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.