HL7 Personal Health Record System Functional Model, Release 2
2.0.1 - Normative

HL7 Personal Health Record System Functional Model, Release 2 - Downloaded Version 2.0.1 See the Directory of published versions

Requirements: TI.2.1 Audit Triggers (Function)

Official URL: http://hl7.org/ehrs/uv/phrsfmr2/Requirements/PHRSFMR2-TI.2.1 Version: 2.0.1
Standards status: Normative Computable Name: TI_2_1_Audit_Triggers

Manage Audit Triggers

Description I: PHR Systems have built in audit triggers to capture key events in real-time. Audit triggers signal key: - Record management and lifecycle events; - Security events related to system and data safeguards, both routine and exceptional; - System events related to performance and operations, both routine and exceptional; - Clinical events with special log requirements.
Criteria N:
TI.2.1#01 SHALL The system SHALL audit key events, as specified in function [TI.2.1](Requirements-PHRSFMR2-TI.2.1.html) (Audit Triggers) and child functions, according to scope of practice, organizational policy, and/or jurisdictional law.
TI.2.1#02 SHALL The system SHALL capture key Audit Metadata at each Audit Trigger, as specified in [TI.2.1](Requirements-PHRSFMR2-TI.2.1.html) (Audit Triggers) and child functions, according to scope of practice, organizational policy, and/or jurisdictional law.
TI.2.1#03 SHALL The system SHALL capture an Audit Log Entry at each Audit Trigger as specified in [TI.2.1](Requirements-PHRSFMR2-TI.2.1.html) (Audit Triggers) according to scope of practice, organizational policy, and/or jurisdictional law.
TI.2.1#04 SHALL The system SHALL capture the current master clock time to establish valid record date and time metadata.
TI.2.1#05 MAY The system MAY manage Audit Trigger logging using a common audit engine (e.g., using schema and transports such as specified in the Audit Log specification of IHE Audit Trails and Node Authentication (ATNA) Profile).