HL7 Personal Health Record System Functional Model, Release 2
2.0.1 - Normative
HL7 Personal Health Record System Functional Model, Release 2 - Downloaded Version 2.0.1 See the Directory of published versions
| Official URL: http://hl7.org/ehrs/uv/phrsfmr2/Requirements/PHRSFMR2-TI.1.5 | Version: 2.0.1 | ||||
| Standards status: Normative | Computable Name: TI_1_5_Non_Repudiation | ||||
Limit a PHR-S user's ability to deny (repudiate) data origination, transmission or receipt by that user.
| TI.1.5#01 | SHALL | The system SHALL capture the identity of the entity taking the action according to scope of practice, organizational policy, and/or jurisdictional law. |
| TI.1.5#02 | SHALL | The system SHALL capture time stamp of the initial entry, modification and exchange of data according to scope of practice, organizational policy, and/or jurisdictional law. |
| TI.1.5#03 | SHALL | The system SHALL conform to function [TI.2](Requirements-PHRSFMR2-TI.2.html) (Audit) to prevent repudiation of data origination, transmission and receipt according to scope of practice, organizational policy, and/or jurisdictional law. |
| TI.1.5#04 | SHOULD | The system SHOULD conform to function [RI.1.1.4](Requirements-PHRSFMR2-RI.1.1.4.html) (Attest Record Entry Content) to ensure integrity of data and data exchange and thus prevent repudiation of data origination, transmission or receipt according to scope of practice, organizational policy, and/or jurisdictional law. |