Validation Results for ClinicalDocumentArchitecture
Generated Wed Dec 18 12:05:32 AEDT 2024, FHIR version 5.0.0 for hl7.cda.uv.core#2.0.1-sd (canonical = http://hl7.org/cda/stds/core (history)). See Full QA Report
Quality Checks |
Publisher Version: | IG Publisher Version: v1.6.0-SNAPSHOT, which is out of date. The current version is v1.8.3 Download Latest |
Publication Code: | n/a . PackageId = hl7.cda.uv.core, Canonical = http://hl7.org/cda/stds/core |
Realm Check for n/a: | |
Language Info: | This IG has no language information |
Publication Request: |
package-id | hl7.cda.uv.core |
version | 2.0.1-sd |
path | http://hl7.org/cda/stds/core/2.0.1-sd |
Pub-Mode | milestone |
status | informative |
Release-Label | release |
Sequence (Group) | CDA 2.0 (current: 'CDA2', others = 'CDA 2.0','CDA 2.1') |
desc | Dec 2024 Published version that is used by CCDA and other guides. |
This release is labelled as a milestone, so should not have a patch version (2.0.1-sd) |
Supressed Messages: | 16 Suppressed Issues
|
Dependency Checks: | Package | Version | FHIR | Canonical | Web Base | Comment |
---|
hl7.cda.uv.core | 2.0.1-sd | R5 | http://hl7.org/cda/stds/core | | |
hl7.fhir.uv.extensions.r5 | 5.1.0 M | R5 | http://hl7.org/fhir/extensions | http://hl7.org/fhir/extensions/5.1.0 | |
hl7.terminology | 5.2.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/5.2.0 | FHIR Version Mismatch. Latest Release is 6.1.0 |
hl7.fhir.uv.extensions.r4 | 1.0.0 O | R4 | http://hl7.org/fhir/extensions | http://hl7.org/fhir/extensions/1.0.0 | FHIR Version Mismatch. Latest Release is 5.1.0 |
Templates: hl7.cda.template#current -> hl7.base.template#current -> fhir.base.template#current. Tools: 0.3.0 |
Dependent IGs: | 1 guide |
Global Profiles: | (none declared) |
Terminology Server(s): | http://tx.fhir.org/r5 (details) |
HTA Analysis: | no Non-HL7 references found |
R5 Dependencies: | (none) |
Draft Dependencies: |
|
Modifier Extensions: | (none) |
Previous Version Comparison: | Comparison with version 2.0.0-sd |
IPA Comparison: | n/a |
IPS Comparison: | n/a |
Validation Flags: | On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings |
Summary: | errors = 0, warn = 2, info = 0, broken links = 0 |
n/a Show Validation Information
| warning | This IG is version 5.0.0, while the IG 'hl7.terminology' is from version 4.0.1 |
| warning | The jira specification file appears to be out of date with the versions, artifacts and pages currently defined in the IG. A proposed revised file to be reviewed and, if appropriate, submitted as a pull request against the XML folder in https://github.com/HL7/JIRA-Spec-Artifacts. To see the differences, perform a file compare on 'template/jira-current.xml' (a normalized view of what is in Github) and 'template/jira-new.xml' (reflects current IG content) |
IG | warning | The IG is not for the international realm, and it uses SNOMED CT, so it should fix the SCT edition in the expansion parameters |
Suppressed Messages (Warnings, hints, broken links)
CASESBJ is the actual code. CASEBJ is what is in THO but that has been verified to be wrong.
- The code 'CASESBJ' is not valid in the system http://terminology.hl7.org/CodeSystem/v3-RoleClass% (4 uses)
CDA type names are UpperCamelCase
- Constraint failed: eld-20: 'The first component of the path should be UpperCamelCase.% (119 uses)
CDA type names have _ in them
- Constraint failed: cnl-0: 'Name should be usable as an identifier for the module by machine processing applications such as code generation'% (15 uses)
Experimental value sets that we are using
- The definition for the element 'AuthoringDevice.manufacturerModelName' binds to the value set 'http://terminology.hl7.org/ValueSet/v3-ManufacturerModelNameExample' which is experimental, but this structure is not labeled as experimental (2 uses)
- The definition for the element 'AuthoringDevice.softwareName' binds to the value set 'http://terminology.hl7.org/ValueSet/v3-SoftwareNameExample' which is experimental, but this structure is not labeled as experimental (2 uses)
- The definition for the element 'Device.manufacturerModelName' binds to the value set 'http://terminology.hl7.org/ValueSet/v3-ManufacturerModelNameExample' which is experimental, but this structure is not labeled as experimental (2 uses)
- The definition for the element 'Device.softwareName' binds to the value set 'http://terminology.hl7.org/ValueSet/v3-SoftwareNameExample' which is experimental, but this structure is not labeled as experimental (2 uses)
Ignore duplicate anchor ids for now
- The html source has duplicate anchor Ids:% (139 uses)
This is an auto-include that we don't control
- This IG is version 5.0.0, while the IG 'hl7.terminology' is from version 4.0.1 (0 uses)
Warnings from the example CDA document
- A code with no system has no defined meaning, and it cannot be validated. A system should be provided (1 uses)
- The CDA Template 2.16.840.1.113883.10.20.22.1.4 / 2024-05-01 is not known (1 uses)
- The CDA Template 2.16.840.1.113883.10.20.22.2.10 / 2014-06-09 is not known (1 uses)
- The code '78615007' is valid but is not active (4 uses)
- The code 'COND' is valid but is deprecated (8 uses)
- xsi:type is unnecessary at this point (2 uses)
We want to fix a bunch of coded fields
- Constraint failed: eld-24: 'pattern[x] should be used rather than fixed[x]' (defined in http://hl7.org/fhir/StructureDefinition/ElementDefinition) (Best Practice Recommendation) (435 uses)
Errors sorted by type